Husqvarna 308 manual Security, Test IN, Drive past wire, Change PIN code, Menu Functions

Models: 308

1 78
Download 78 pages 38.21 Kb
Page 49
Image 49
Test IN

6. MENU FUNCTIONS

Test IN

The Test IN function allows you to test how well the robotic lawnmower docks with the charging station.

Test IN can only be performed after Test OUT has been performed.

Selecting this function causes the mower to travel directly along the guide wire towards the charging station and docks with it. The test is approved only if the mower is able to dock with the charging station at the first attempt. If the mower is unable to dock on the first attempt, it will automatically try again. The installation is not approved if the mower needs two or more attempts to dock with the charging station.

Drive past wire

The front of the mower always passes the boundary wire by a specific distance before the mower turns. The default distance is 25 cm, but this can be changed if required. The minimum value is 25 cm and the maximum value is 30 cm.

Now specify the number of centimetres you want the mower to pass the boundary wire and press OK.

Guide width

Remote start 1

Remote start 2 Test settings Drive past wire

6.5 Security

 

 

Through this selection, settings relating to security

 

 

Timer

 

and the connection between the mower and the

 

 

 

charging station can be made.

Installation

 

 

 

Change PIN code

 

 

Enter the new PIN code and press OK. Enter the

Security

 

 

 

 

same code again and confirm by pressing OK. When

 

 

the PIN code is changed, a message stating that the

Settings

 

PIN code has been changed appears in the display

 

 

momentarily.

 

 

 

 

Make a note of the new PIN code on the designated

 

 

line in Memo on page 4.

 

 

Change PIN code

Security level

New loop signal

English - 49