4. USE
If the timer setting is divided into two work periods, the standby period can be divided into a number of periods. The total standby time must however be at least 6 hours (8 hours for Automower® 305).
Example 2
The times used in this example are applicable to the Automower® 305 but the principle is the same for the Automower® 308.
Work period 1: 08:00 - 16:00
Work period 2: 20:00 - 23:00
Work days: All days
The robotic lawnmower will operate for the times specified in the work periods as the total operating time is 11 hours and does not exceed the maximum of 16 hours.
| Automower® | Automower® |
| 305 | 308 |
|
|
|
|
|
|
Max. operating time | 16 h | 18 h |
|
|
|
Min. standby time | 8 h | 6 h |
|
|
|
Area/hour/day | 30 m2 | 45 m2 |
The times are approximate and depend for instance on grass quality, blade sharpness and battery age.
4.3 Starting
1.Set the main switch to position 1.
2.Press the STOP button to open the control panel cover.
3.Enter the PIN code.
The PIN code request can be disabled. For more information about
6.5 Security.
4.Push the Start button.
5.Shut the cover within 10 seconds.
If the robotic lawnmower is parked in the charging station, it will only leave the charging station when the battery is fully charged and if the timer is set to allow the mower to operate.
Before the blade disc starts, 5 beeps are heard for 2 seconds.
305 |
|
Operation | A + C = Max 16 h |
Charging/Standby | B + D = Min 8 h |
308 |
|
Operation | A + C = Max 18 h |
Charging/Standby B + D = Min 6 h
English - 37