![MERCHANDISER ELECTRICAL DATA](/images/new-backgrounds/70918/7091843x1.webp)
MERCHANDISER ELECTRICAL DATA
Merchandiser data sheets are shipped with this manual. The data sheets provide case electrical data, electrical schematics, parts lists and performance data. Refer to the merchandiser data sheets and case serial plate for electrical information.
ELECTRICAL CONNECTIONS
All wiring must be in compliance with NEC and local codes. All electrical connections are to be made in the electrical raceway or Handy Box.
FIELD WIRING
Field wiring must be sized for component amperes stamped on the serial plate. Actual ampere draw may be less than specified. Field wiring from the refrigeration control panel to the merchandisers is required for defrost termi- nation thermostats and for optional refrigeration thermostats. When multiple merchandisers are on the same defrost circuit, the defrost termina- tion
thermostats are wired in series. ALWAYS
CHECK THE SERIAL PLATE FOR COMPONENT AMPERES.
IDENTIFICATION OF WIRING
Leads for all electrical circuits are identified by colored plastic bands. These bands correspond to the color code sticker (shown below) located inside the merchandiser’s raceway.
WIRING COLOR CODE
Leads for all electrical circuits are identified by a colored plastic band: neutral wire for each circuit has either White insulation or a White plastic sleeve in addition to the color band.
PINK | REFRIG. THERMOSTAT LOW TEMP. | ORANGE OR | ||
LIGHT BLUE .. | REFRIG. THERMOSTAT NORM TEMP. | TAN | LIGHTS | |
DARK BLUE .. | DEFROST TERM. THERMOSTAT | MAROON... | RECEPTACLES | |
PURPLE | CONDENSATE HEATERS | YELLOW .... | DEFROST HEATERS 120V | |
BROWN | FAN MOTORS |
| RED | DEFROST HEATERS 208V |
GREEN* | GROUND | *EITHER COLORED SLEEVE OR COLORED INSULATION |
ELECTRICIAN NOTE: Use copper conductor wire only.
CASE MUST BE GROUNDED
P/N 0420057_B | U.S. & Canada |