hussman P/N 0420057_B Drip Piping And Splashguards, P/N 0420057B, Waste Outlet And Water Seal

Models: P/N 0420057_B

1 46
Download 46 pages 55.32 Kb
Page 23
Image 23
DRIP PIPING AND SPLASHGUARDS

P/N 0420057_B

3-1

DRIP PIPING AND SPLASHGUARDS

WASTE OUTLET AND WATER SEAL

The waste outlet is located in front of the fan plenum 6 ft (1829 mm) from the left-hand of the merchandiser (facing case front) allowing drip piping to be run under the fixture lengthwise.

A11/2 in. (38 mm) water seal is supplied with each fixture. The water seal must be installed to prevent air leakage and insect entrance into the fixture. A tee, adapter, ell, and plug have been shipped to allow field installation to determine direction of drain.

NOTES:

Water seal outlet must clear front skid rail. PVC–DWV solvent cement is recommended. Follow the manufacturer’s instructions.

INSTALLING DRIP PIPING

Poorly or improperly installed drip pipes can seriously interfere with the operation of these merchandisers, and result in costly maintenance and product losses. Please follow the recommen- dations listed below when installing drip pipes to ensure proper installation.

1.Never use drip piping smaller than the nominal diameter of the pipe or water seal supplied with the merchandiser.

2.When connecting drip piping, the water seal must be used as part of the drip piping to prevent air leakage or insect entrance. Never use two water seals in series in any one drip pipe. Double water seals in series will cause an air lock and prevent draining.

3.Pitch the drip piping in the direction of flow. There should be a minimum pitch of 1/8 in. per foot (3 mm per 300 mm).

4.Avoid long runs of drip piping. Long runs make it impossible to provide the pitch necessary for good drainage.

5. Provide a suitable air break between flood rim of the floor drain and outlet of drip pipe. To meet code on low base merchandisers, it may be necessary to install a field-supplied drip pipe reducer. An alternative is to cut the last section of drip pipe at an angle.

6.Prevent drip pipes from freezing:

A.Do NOT install drip pipes in contact with uninsulated suction lines. Suction lines should be insulated with a non-absorbent insulation material.

B.Where drip pipes are located in dead air spaces, such as between merchandisers or between a merchandiser and a store wall, provide means to prevent freezing.

Note: To prevent condensation problems, the water seal should be insulated.

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

Service Merchandisers