P/N 0420057_B
ELECTRICAL SERVICE RECEPTACLES
The receptacles located on the exterior back of the merchandisers are intended for scales and other light duty appliances that are found in meat and delicatessen departments. The receptacles are not intended for large motors.
REPLACING FLUORESCENT LAMPS
Fluorescent lamps are furnished with moisture resistant lamp holders and end caps. Lamps on lighted shelves have plastic shields. Whenever a fluorescent lamp is replaced, be certain to re- install the plastic shields and end caps.
Plastic Shield
Fluorescent
Lamp
End Cap
!CAUTION
Fluorescent lamps contain mercury vapor. Mercury exposure at high levels can harm the brain, heart, kidneys, lungs, and immune system of people of all ages. Do not break or puncture fluorescent lamps. Dispose of, or store, all fluorescent lamps in accordance with Federal (40 CFR 273), State, and local hazardous waste requirements. Refer to http://www.epa.gov/mercury/about.htm
REPLACING LAMP HOLDERS AND END CAPS
The Hussmann Impact lamp holder is designed to snap into the sheet metal of the case. The lamp holder has a locking ‘nub’ which fits inside the groove of specially designed end caps.
Hussmann | Groove |
Impact |
|
|
Nub
Hussmann
Impact
Lamp Holder
IMPORTANT!
Always replace lamp holders and end caps with Hussmann lamp holders and end caps.
Use of
HUSSMANN CORPORATION, Bridgeton, MO | Service Merchandisers |