hussman manual EKC 201 CONTROLLERS, Quick guide, IGSSB-SCSS / SCSS-SL-0108, → +55C, → +50C

Models: SCSS SCSS-SL

1 24
Download 24 pages 45.19 Kb
Page 10
Image 10
EKC 201 CONTROLLERS

IGSSB-SCSS / SCSS-SL-0108

EKC 201 CONTROLLERS

EKC 201

= 0

+55°C

troom

tsystem = –60

+50°C

12 V a.c./230 V a.c.

2.5 VA

IP 54

Fig. 1

Quick guide

Identification

(See figs 1 and 2).

1.Light emitting diode

→ +55°C = refrigeration

→ +50°C = defrost

12 V a.c./230 V a.c. = fan running

2.Minus sign

3.Display

(Flashes when setting value for room temp. is displayed).
4.Keys for programming and setting (see programming instructions).
Programming and setting
see programming instructions, parameter code, and settings.
Quick guide Press upper key for 2 s.

Identification Press lower key for 2 s.

(See figs 1 and 2). Press both keys at the same time.

What

Initial

 

Operating the two pushbuttons

 

Resulting

controller

 

 

Display

 

controller

to do

 

 

 

 

 

 

readout

 

 

Read

Normal

 

Set

 

Room

Normal

or

operation

 

value

temp.

operation

change

 

 

 

 

 

 

room

 

Room

 

Change

Room

Room

temp.

Room

temp.

 

temp.

 

 

 

 

 

 

Read

Normal

 

Code

Set

 

Normal

operation

 

value

 

operation

or change

 

 

 

(or alarm)

 

 

 

 

(or alarm)

parameter

 

 

 

 

 

Room

 

 

Room

 

codes

Unknown

Change

Change

 

temp.

temp.

Known

and

 

 

codes

 

 

 

 

codes

 

 

 

 

 

 

 

 

 

 

 

All

Re-establish

Unknown

Room

 

Power

Room

parameter

all factory

Power off

settings

settings

temp.

on

temp.

 

 

= factory

 

 

 

 

 

 

Read

Normal

Room

 

 

Room

Normal

defrost

 

Defrost sensor temp.

sensor

operation

temp.

 

 

temp.

operation

 

 

 

 

 

or alarm

 

 

 

 

 

Manually

 

 

 

Defrost operation

 

 

 

 

 

 

 

 

start of

Normal

Room

 

 

Room

Normal

a defrost

operation

temp.

 

 

temp.

operation

 

 

 

 

Room temp.

 

 

Manually

 

 

 

 

 

 

stop of

Defrost

Room

 

Room temp.

Room

Normal

a defrost

operation

temp.

 

temp.

operation

 

 

Reset

Alarm

 

 

 

 

Alarm

Room

 

Alarm code/

Room

relay

alarm

relay

 

temp.

 

Fault code

temp.

not

relay

 

 

 

 

 

 

 

 

Read codes

Alarm relay

Room

 

Alarm code/

Room

Alarm

cause of

not

 

temp.

 

Fault code

temp.

 

alarm mode

activated

 

 

 

 

 

 

 

 

 

 

10

 

Page 10
Image 10
hussman EKC 201 CONTROLLERS, Quick guide, IGSSB-SCSS / SCSS-SL-0108, 12 V a.c./230 V a.c 2.5 VA IP, → +55C, → +50C