REPLACING FLUORESCENT LAMPS

IGSSB-SCSS / SCSS-SL-0108

Maintenance

BEFORE SERVICING – Always disconnect electrical power at the main disconnect when servicing or replacing any electrical component

This includes (but not limited to) Fans, Heaters,

Thermostats, and Lights.

REPLACING FLUORESCENT LAMPS

Fluorescent lamps are furnished with a shatterproof pro- tective coating. The same type of lamp with protective coating must be used if replaced.

This lamp has been treated to resist breakage and must be replaced with a similarly treated lamp in order to maintain

compliance with NSF Standards.

NSF CODE 4.28.1

Contact HUSSMANN Chino for replacement

1-800-395-9229

x 2131

T-5 BULBS

COPPER COILS

The copper coils used in Hussmann merchandisers may be repaired in the field. Materials are available from local refrigeration wholesalers.

Hussmann recommends using #15 Sil-Fos for repairs.

TIPS & TROUBLESHOOTING

Before calling for service, check the following:

1.Check electrical power supply to the equipment for connection.

2.Check fixture loading. Overstocking case will affect its proper operation.

3.If frost is collecting on fixture and/or product, check that Humidity Control is working properly, and that no outside doors or windows are open—allowing moisture to enter store.

Please note:T-5 lights must be turned off and on after bulb replacement.

EVAPORATOR FANS

The evaporator fans are located at the center front of these merchandisers directly beneath the display pans. Should fans or blades need servicing, always replace fan blades with the raised embossed side of the blade TOWARD THE MOTOR.

FOR PROMPT SERVICE

When contacting the factory,

be sure to have the Case Model and Serial Number handy. This information is on a plate located on the case itself.

Electrical and Refrigeration Specifications

Model

Refrigeration

 

 

Average

 

Disch. Air

T~Stat

Coil Type

Fan Blade

 

Defrosts

Electrical Load (Amps) @ ~115 VAC

 

Condensing Unit Data

 

&

Btu / Hr.

 

Temperatures (°F)

 

Speed

Settings

Size (in) &

Evap.

Motors

per day

Evap.Fans Case

Case

Defrost

Glass

Set (PSI)

Size

Voltage

Ampacity

Length

(Ft.)

(Total)

Evap.

Prod.

Disch.

(CFM)

(°F)

pitch ( ° )

Fans

Qty

Length Qty

Fans Warmer

Lights

Heater

Heater

Out

In

(HP)

(VAC)

SCSS-M Medium Temperature

4'

650

2,600

20°

40°

30°

200

Optional Forced Air

4" Axial

2

30

2

0.28

0.35

0.54

 

 

30

50

1/2

115

13.6

5'

650

3,250

20°

40°

30°

200

Optional Forced Air

4" Axial

2

30

2

0.28

0.43

0.54

 

 

30

50

3/4

115

18.5

6'

650

3,900

20°

40°

30°

200

Optional Forced Air

4" Axial

3

30

2

0.42

0.52

0.54

 

 

30

50

3/4

115

18.5

8'

650

5,200

20°

40°

30°

200

Optional Forced Air

4" Axial

4

30

2

0.56

0.70

0.54

 

 

30

50

1

208~230 11.8

SCSS-M

Low Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4'

800

3,200

-25°

-10°

-20°

200

Optional Forced Air

4" Axial

2

20

1

0.28

0.35

0.54

5.77

0.42

30

50

1-1/2

208

14.7

5'

800

4,000

-25°

-10°

-20°

200

Optional Forced Air

4" Axial

2

20

1

0.28

0.43

0.54

9.62

0.52

30

50

1-1/2

208

14.7

6'

800

4,800

-25°

-10°

-20°

200

Optional Forced Air

4" Axial

3

20

1

0.42

0.52

0.54

9.62

0.63

30

50

1-1/2

208

14.7

8'

800

6,400

-25°-10°

-20°

200

Optional Forced Air

4" Axial

4

20

1

0.56

0.70

0.54

10.82

0.63

30

50

2

208

12.8

SCSS-SLM

Slim Line - Medium Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4'

540

2,160

20°

40°

30°

200

Optional Forced Air

4" Axial

2

30

2

0.28

0.35

0.54

 

 

30

50

1/2

115

13.6

5'

540

2,700

20°

40°

30°

200

Optional Forced Air

4" Axial

2

30

2

0.28

0.43

0.54

 

 

30

50

3/4

115

18.5

6'

540

3,240

20°

40°

30°

200

Optional Forced Air

4" Axial

3

30

2

0.42

0.52

0.54

 

 

30

50

3/4

115

18.5

8'

540

4,320

20°

40°

30°

200

Optional Forced Air

4" Axial

4

30

2

0.56

0.70

0.54

 

 

30

50

1

208 ~ 23011.8

SCSS-SLLSlim Line - Low Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4'

625

2,500

-25°

-10°

-20°

200

Optional Forced Air

4" Axial

2

20

1

0.28

0.35

0.54

5.77

0.42

30

50

1-1/2

208

14.7

5'

625

3,125

-25°

-10°

-20°

200

Optional Forced Air

4" Axial

2

20

1

0.28

0.43

0.54

9.62

0.52

30

50

1-1/2

208

14.7

6'

625

3,750

-25°

-10°

-20°

200

Optional Forced Air

4" Axial

3

20

1

0.42

0.52

0.54

9.62

0.63

30

50

1-1/2

208

14.7

8'

625

5,000

-25°

-10°

-20°

200

Optional Forced Air

4" Axial

4

20

1

0.56

0.70

0.54

10.82

0.63

30

50

2

208

12.8

14

Page 14
Image 14
hussman SCSS-SL manual Replacing Fluorescent Lamps, Tips & Troubleshooting, Before calling for service, check the following