Notes:
1. For details about the BladeCenter unit port specifications, see “Input/output connectors” on page 26.
2. For information about which types of I/O modules can be installed in which I/O-module bays, see “I/O modules” on page 16.
3. The operating system in the blade server must provide USB support for the blade server to recognize and use the keyboard, mouse, CD-ROM drive, and diskette drive. The BladeCenter unit uses USB for internal communication with these devices.
– Power modules 1 and 2 provide redundancy to each other
– Power modules 3 and 4 provide redundancy to each other

Features and specifications

The following table provides a summary of the features and specifications for your BladeCenter unit.

Table 1. Features and specifications

Media tray (on front):

I/O modules:

v Diskette drive: 1.44 MB

v

Standard: None

v CD-ROM drive: IDE

v

Maximum: Four

v Universal Serial Bus (USB) v1.1 port

 

 

 

v Front system LED panel

Management module:

 

 

Module bays (on rear):

v Standard: One hot-swap management

v

Four hot-swap 220-volt

 

module providing the following features:

v

power-module bays

 

System-management functions for

Two hot-swap management-module

 

 

the BladeCenter system

 

bays

 

Video port (analog)

v Four hot-swap I/O-module bays

 

 

PS/2® keyboard port

v Two hot-swap blower bays

 

Blade bays (on front):

 

PS/2 mouse port

 

– 10/100 Mb Ethernet remote

 

 

 

14 hot-swap blade bays

 

 

management connection

v Maximum: Two hot-swap management

Redundant cooling:

 

modules: one active, one redundant

Two variable-speed hot-swap blowers

Upgradeable microcode:

Power modules:

v

Management module firmware

v I/O module firmware (not all I/O module

v Standard: Two 1200-watt or greater

 

types)

 

220-volt (200-240 V ac) hot-swap

v Blade server service processor firmware

 

power modules

 

– Both power modules supply 12 V

Security features:

 

power to all modules and to blade

 

v Login password for remote connection

 

bays 1 through 6

 

– Both power modules provide

v Secure socket layer (SSL) security for

 

redundancy to each other

 

remote management access

 

 

 

 

v

Maximum: Four

Predictive Failure Analysis® (PFA)

 

– Power modules 1 and 2 supply 12

alerts:

 

V to all modules and to blade

v

Blowers

 

bays 1 through 6

v

Blade-dependent features

Power modules 3 and 4 supply 12 Size (7U): V to blade bays 7 through 14

v Height: 304.2 mm (12 in. or 7 U)

v Depth: 711.2 mm (28 in.)

v Width: 444 mm (17.5 in.) v Weight:

– Fully configured with modules and blades: Approx. 108.86 kg (240 lb)

– Fully configured without blades: Approx. 44.91 kg (99 lb)

Acoustical noise emissions:

vWithout acoustics module option:

Sound power, idle: 7.4 bels maximum

Sound power, operating: 7.4 bels maximum

vWith acoustics module option:

Sound power, idle: 6.9 bels maximum

Sound power, operating: 6.9 bels maximum

Environment:

vAir temperature:

BladeCenter unit on: 10° to 35°C (50° to

95°F). Altitude: 0 to 914 m (2998.69 ft)

BladeCenter unit on: 10° to 32°C (50° to

89.6°F). Altitude: 914 m to 2134 m (2998.69 ft to 7000 ft)

BladeCenter off: -40° to 60° C (-40° to 140° F).

vHumidity:

Server on: 8% to 80%

Server off: 8% to 80%

Electrical input:

vSine-wave input (50-60 Hz single-phase) required

vInput voltage:

Minimum: 200 V ac

Maximum: 240 V ac

Heat output:

Approximate heat output in British thermal units (Btu) per hour

vMinimum configuration: 1365 Btu/hour (400 watts)

vMaximum configuration: Varies depending on the type of power supplies installed.

Four 1200-watt power supplies: 9622 Btu/hour (2820 watts)

Four 1400-watt power supplies: 11111 Btu/hour (3256 watts)

For all other power supplies, see the documentation that comes with the power supply.

6BladeCenter Type 8677: Installation and User’s Guide

Page 20
Image 20
IBM 8677 manual Features and specifications