Table 3. Light path diagnostics (continued)

Lit LED

Cause

Action

 

 

 

Power module

 

 

 

 

 

System error

A critical error has occurred in the power

Reseat the power module. If the problem

 

module.

remains, replace the module.

 

 

If your BladeCenter unit has a redundant

 

 

module for this power module, the BladeCenter

 

 

unit continues to function using the redundant

 

 

module.

 

 

 

Blower module

 

 

 

 

 

System error

The blower has failed or is operating too

Reseat the blower module. If the problem

 

slowly.

remains, replace the blower module as soon

 

 

as possible, to regain cooling redundancy.

 

 

The BladeCenter unit continues to function.

 

 

The redundant blower module provides cooling

 

 

to the BladeCenter unit and blade servers.

 

 

 

I/O module

 

 

 

 

 

System error

A critical error has occurred in the I/O module.

Reseat the I/O module. If the problem remains,

 

 

replace the module.

 

 

 

58BladeCenter Type 8677: Installation and User’s Guide