I/O modules

For blade server communication with the network, your BladeCenter unit supports from one to four hot-swap I/O modules. Table 2 identifies the type of I/O module you can install in each I/O-module bay. Go to the IBM Support Web site at http://www.ibm.com/pc/support/ to see the list of supported I/O modules.

Your BladeCenter unit supports a minimum of one hot-swap Ethernet switch module or pass-thru module, in I/O-module bay 1 or 2. This I/O module provides an internal connection to an integrated Ethernet controller in all the blade servers in the BladeCenter unit, up to 14 internal connections per I/O module. To provide an internal connection for the second integrated Ethernet controller in each blade server, install an Ethernet switch module or pass-thru module in the available I/O-module bay of the pair (I/O-module bay 1 or bay 2).

Similarly, the BladeCenter unit supports two additional I/O modules in I/O-module bays 3 and 4. Each of these I/O modules provides an internal connection to one of the two network-interface controllers on all the I/O expansion options installed on blade servers in the BladeCenter unit. The I/O module must be compatible with the network interface on all the I/O expansion options. For example, if you install a Fibre Channel I/O expansion option on a blade server, the I/O modules you install in I/O-module bays 3 and 4 must be Fibre Channel switch modules or pass-thru modules.

Notes:

1.Because of electromagnetic interference (EMI), no more than two four-port 1-Gb Ethernet switch modules can be installed in the BladeCenter unit. You can mix four-port 1-Gb Ethernet switch modules with other supported Ethernet switch modules to achieve the total number of Ethernet switch modules you need in the BladeCenter unit.

2.You can use a pass-thru module in any I/O-module bay, provided the associated controller in the blade servers or I/O expansion options is compatible with it.

The following table summarizes the types of modules that can be used in each I/O-module bay. See “Rear view” on page 33 for the location of the I/O-module bays on the BladeCenter unit.

Table 2. Hot-swap I/O module types by location

Bays

I/O-module function

Permissible I/O module

1 and 2 Network connections 1 and 2

One of the following combinations:

 

(Ethernet) for all blade servers in the

v Two Ethernet switch modules

 

BladeCenter unit

v Two pass-thru modules

 

 

 

 

v One Ethernet switch module and

 

 

one pass-thru module

 

 

3 and 4 Network connections 3 and 4 (for all

One of the following combinations.

 

I/O expansion options on blade

v Two Ethernet switch modules

 

servers in the BladeCenter unit)

v Two Fibre Channel switch modules

 

 

 

 

v Two pass-thru modules

Important:

v The modules used must support the

network interface used on the I/O expansion options.

v The I/O modules in bays 3 and 4 must be the same type.

16BladeCenter Type 8677: Installation and User’s Guide

Page 30
Image 30