IBM manual Non-switched FC-AL drawbacks, DS8000 disk enclosure

Models: DS8000

1 450
Download 450 pages 61.48 Kb
Page 54
Image 54

Figure 2-9 DS8000 disk enclosure

Non-switched FC-AL drawbacks

In a standard FC-AL disk enclosure all of the disks are arranged in a loop, as depicted in Figure 2-10.This loop-based architecture means that data flows through all disks before arriving at either end of the device adapter (shown here as the Storage Server).

Figure 2-10 Industry standard FC-AL disk enclosure

The main problems with standard FC-AL access to DDMs are:

￿The full loop is required to participate in data transfer. Full discovery of the loop via LIP (loop initialization protocol) is required before any data transfer. Loop stability can be affected by DDM failures.

￿In the event of a disk failure, it can be difficult to identify the cause of a loop breakage, leading to complex problem determination.

￿There is a performance dropoff when the number of devices in the loop increases.

￿To expand the loop it is normally necessary to partially open it. If mistakes are made, a complete loop outage can result.

32DS8000 Series: Concepts and Architecture

Page 54
Image 54
IBM manual Non-switched FC-AL drawbacks, DS8000 disk enclosure