IBM DS8000 manual Host connection availability, Single or multiple path

Models: DS8000

1 450
Download 450 pages 61.48 Kb
Page 93
Image 93

The single purpose of the batteries is to preserve the NVS area of server memory in the event of a complete loss of input power to the DS8000. If both power supplies in the base frame were to stop receiving input power, the servers would be informed that they were now running on batteries and immediately begin a shutdown procedure. Unless the power line disturbance feature has been purchased, the BBUs are not used to keep the disks spinning. Even if they do keep spinning, the design is to not move the data from NVS to the FC-AL disk arrays. Instead, each processor complex has a number of internal SCSI disks which are available to store the contents of NVS. When an on-battery condition related shutdown begins, the following events occur:

1.All host adapter I/O is blocked.

2.Each server begins copying its NVS data to internal disk. For each server, two copies are made of the NVS data in that server.

3.When the copy process is complete, each server shuts down AIX.

4.When AIX shutdown in each server is complete (or a timer expires), the DS8000 is powered down.

When power is restored to the DS8000, the following process occurs:

1.The processor complexes power on and perform power on self tests.

2.Each server then begins boot up.

3.At a certain stage in the boot process, the server detects NVS data on its internal SCSI disks and begins to destage it to the FC-AL disks.

4.When the battery units reach a certain level of charge, the servers come online.

An important point is that the servers will not come online until the batteries are fully charged. In many cases, sufficient charging will occur during the power on self test and storage image initialization. However, if a complete discharge of the batteries has occurred, which may happen if multiple power outages occur in a short period of time, then recharging may take up to two hours.

Because the contents of NVS are written to the internal SCSI disks of the DS8000 processor complex and not held in battery protected NVS-RAM, the contents of NVS can be preserved indefinitely. This means that unlike the DS6000 or ESS800, you are not held to a fixed limit of time before power must be restored.

4.5 Host connection availability

Each DS8000 Fibre Channel host adapter card provides four ports for connection either directly to a host, or to a Fibre Channel SAN switch.

Single or multiple path

Unlike the DS6000, the DS8000 does not use the concept of preferred path, since the host adapters are shared between the servers. To show this concept, Figure 4-5 on page 72 depicts a potential machine configuration. In this example, a DS8100 Model 921 has two I/O enclosures (which are enclosures 2 and 3). Each enclosure has four host adapters: two Fibre Channel and two ESCON. I/O enclosure slots 3 and 6 are not depicted because they are reserved for device adapter (DA) cards. If a host were to only have a single path to a DS8000 as shown in Figure 4-5,then it would still be able to access volumes belonging to all LSSs because the host adapter will direct the I/O to the correct server. However, if an error were to occur either on the host adapter (HA), host port (HP), or I/O enclosure, then all connectivity would be lost. Clearly the host bus adapter (HBA) in the attached host is also a single point of failure.

Chapter 4. RAS 71

Page 93
Image 93
IBM DS8000 manual Host connection availability, Single or multiple path