M a i n t e n a n c e

After you make sure that the condition that made the fuse blow no longer exists, follow these steps to replace the fuse:

1Turn off the projector by pressing the “O” side of the power switch.

2Unplug the power cord.

3Remove the fuse holder, located just above the power cord connector. Pull out the fuse holder with a small, flat-blade screwdriver, key or coin (Figure 40).

CAUTION: The 6.3A IEC 127 type fuse is required in Europe. In countries with low main voltage, you may need the 8.0A fuse to avoid repeated (nuisance) blowing of the 6.3A fuse. Both fuses provide protection from risk of fire. Do not use the projector if repeated blowing still occurs after switching to the 8.0A fuse. Call In Focus Technical Support for assistance.

FIGURE 40

Removing the fuse holder

4Remove the blown fuse from the fuse holder (Figure 41).

FIGURE 41

Removing the fuse from the fuse holder

5Push the spare fuse into the holder until it is securely seated.

6Place the fuse holder back in position (Figure 42).

46

Page 59
Image 59
InFocus 220, 210 manual Remove the blown fuse from the fuse holder Figure