Input Connection Examples

Input Connection Examples

The following diagrams illustrate possible connection/application of the MDriveAC Plus Microstepping Logic Inputs.

Open Collector Interface Example

NPN Open Collector Interface

(Sinking)

+5 to +24VDC

+

Controller Output

Optocoupler Reference

MDriveACPlus Microstepping

Input

Controller Ground

PNP Open Collector Interface

(Sourcing)

+5 to +24VDC

Open Collector Interface Example+

Controller Output

Controller Ground

Optocoupler Reference

MDriveACPlus Microstepping

Input

Figure 2.1.5: Open Collector Interface Example

Part 2: Interfacing and Configuring

2-7

Page 36
Image 36
Intelligent Motion Systems MDrive34AC manual NPN Open Collector Interface Sinking, MDriveACPlus Microstepping