Intelligent Motion Systems MDrive34AC manual Step/Direction Timing, Quadrature Timing, Channel A

Models: MDrive34AC

1 81
Download 81 pages 35.76 Kb
Page 34
Image 34
STEP/DIRECTION TIMING

STEP/DIRECTION TIMING

 

 

 

 

TDH

 

 

Direction

 

 

 

 

TDSU

 

 

 

 

 

 

 

 

 

Step

 

TSL

 

 

 

 

TSH

 

QUADRATURE TIMING

Direction Change

TCHL

 

Channel A

 

 

TDC

Channel B

 

 

TCHL

UP/DOWN (CW/CCW) TIMING

Step Up

 

 

 

 

 

 

 

 

 

Step Down

TSH

TSL

TDC

 

 

 

 

TDC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TSH

TSL

 

 

 

 

Figure 2.1.3: Clock Input Timing Characteristics

 

 

 

 

 

 

 

 

 

 

 

 

 

Clock Input Timing

 

 

Symbol

 

Parameter

 

 

 

Type and Value

 

 

Step/Direction

 

Step Up/Down
Quadrature

Units

 

 

 

 

TDSU

T Direction Set Up

0

 

 

nS min

TDH

T Direction Hold

50

 

 

nS min

TSH

 

T Step High

250

 

 

250

nS min

TSL

 

T Step Low

250

 

 

250

nS min

TDL

T Direction Change

 

250

250

nS min

TCHL

T Channel High/Low

 

400

nS min

FSMAX

F Step Maximum

5

 

 

2

MHz Max

FCHMAX

F Channel Maximum

 

1.25

MHz Max

FER

F Edge Rate

 

5

MHz Max

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Turn On

 

 

Turn Off

µS

Enable On/Off

25

 

 

 

20

µS

 

 

 

 

 

 

 

 

 

 

Table 2.1.1: Input Clocks Timing Table

Part 2: Interfacing and Configuring

2-5

Page 34
Image 34
Intelligent Motion Systems MDrive34AC Step/Direction Timing, Quadrature Timing, Up/Down Cw/Ccw Timing, Channel A, Step Up