Optocoupler Reference

NOTE: When connecting the Optocoupler Supply, it is recommended

that you do not use MDriveAC Plus Power Ground as Ground as this will defeat the optical isolation.

Optocoupler Reference

The MDriveAC Plus Microstepping Logic Inputs are optically isolated to prevent electrical noise being coupled into the inputs and causing erratic operation.

There are two ways that the Optocoupler Reference will be connected depending whether the Inputs are to be configured as sinking or sourcing.

 

Optocoupler Reference

Input Type

 

Optocoupler Reference Connection

Sinking

 

+5 to +24 VDC

Sourcing

 

Controller Ground

Table 2.1.2: Optocoupler Reference Connection

 

 

+5 VDC

Optocoupler

 

 

Reference

 

Optocoupler

 

Constant

 

To Drive Logic

 

Current

 

Input

Source

 

(Step Clock,

 

 

Direction, Enable)

 

 

 

MDriveACPlus

 

 

Microstepping

Figure 2.1.4: Optocoupler Input Circuit Diagram

2-6

MDriveAC Plus Microstepping Hardware - Revision R031808

 

Relevant to Firmware Version 3.0.02

Page 35
Image 35
Intelligent Motion Systems MDrive34AC manual Optocoupler Reference, MDriveACPlus, Microstepping