Setup Parameters
The following table illustrates the setup parameters. These are easily configured using the IMS SPI Motor Interface configuration utility. An optional Parameter Setup Cable is available and recommended with the first order.
Microstepping MForce PowerDrive Setup Parameters
Name | Function | Range | Units | Default | |
|
|
|
|
| |
MHC | Motor Hold Current | 0 to 100 | percent | 5 | |
|
|
|
|
| |
MRC | Motor Run Current | 1 to 100 | percent | 25 | |
|
|
|
|
| |
|
| 1, 2, 4, 5, 8, 10, 16, 25, 32, 50, | µsteps per |
| |
MSEL | Microstep Resolution | 64, 100,108, 125, 127,128, | 256 | ||
full step | |||||
|
| 180, 200, 250, 256 |
| ||
|
|
|
| ||
DIR | Motor Direction Override | 0/1 | – | CW | |
|
|
|
|
| |
HCDT | Hold Current Delay Time | 0 or | mSec | 500 | |
|
|
|
|
| |
CLK TYPE | Clock Type | Step/Dir. Quadrature, Up/Down | – | Step/Dir | |
(CW/CCW) | |||||
|
|
|
| ||
CLK IOF | Clock and Direction Filter | 50 nS to 12.9 µS | nS (MHz) | 200nS(2.5 | |
(10 MHz to 38.8kHz) | MHz) | ||||
|
|
| |||
USER ID | User ID | Customizable | IMS | ||
|
|
|
|
| |
WARN TEMP | Warning Temperature | 0 to +125 | ºC | 80 | |
|
|
|
|
| |
EN ACT | Enable Active High/Low | High or Low | — | High | |
|
|
|
|
| |
PWM MSK | PWM Mask | 0 to 255 | — | 102 | |
|
|
|
|
| |
PWM PER | PWM Duty Cycle | 0 to 95 | Percent | 90% | |
|
|
|
|
| |
PWM FREQ | PWM Frequency Range | 0 to 255 | — | 170 (20kHz to | |
60 kHz) | |||||
|
|
|
| ||
PWM CTL | PWM Control | See Section 2.4 | See Section 2.4 | ||
|
|
|
|
|
Table 1.2.6: Setup Parameters
Mechanical Specifications - Dimensions in Inches (mm)
2.116
(53.75)
2X 0.580
(2X 14.73)
0.225
(5.72)
3.473
(88.21)
P1P3
P4 |
3.00±0.01
(76.2 ±0.25)
0.308 TYP.
(7.82 TYP.)
Ø 0.187 ±0.01 | 3.897 |
|
| |
(98.98) |
|
| ||
(Ø 4.75 ±0.25) |
|
| ||
|
|
| ||
2X #8 Screws | 2.931 TYP. | |||
for End Mount | ||||
(74.45 TYP.) | ||||
|
0.417 TYP. | 2.950 |
(10.59 TYP.) | (74.93) |
3.473
(88.21)
0.160 ±0.01
(4.06 ±0.25)
Ø0.160 ±0.01 Thru (Ø 4.06 ±0.25 Thru) 4X #6 Screws
for Flat Mount
Figure 1.2.1: MForce PowerDrive Mechanical Specifications
Microstepping MForce PowerDrive Manual Revision R032008 |