Intelligent Motion Systems Motion Detector Example B Motor Cabling Greater Than 50 Feet

Models: Motion Detector

1 74
Download 74 pages 21.4 Kb
Page 37
Image 37
Example B: Motor Cabling Greater Than 50 Feet

Example B: Motor Cabling Greater Than 50 Feet

Common Mode

Line Filters (2x)

*L ζ 0.5 MH

A MotorFigure 2.3.8: Motor Cableing Greater than 50 FeetRecommended Motor Cable AWG Sizes

PowerDriveMForce A MForce PowerDrive Recommended Motor Cable AWGTable 2.3.1: Recommended Wire Gauges Phase Outputs B Manual background

B Manual backgroundManual backgroundManual background

Shield to Earth Ground on Supply End Only

Cable Length

as required

Shielded/Twisted Pair

Ferrite Beads Manual background

Motor

Connections

Manual background A

Manual background A

Manual background B Manual background B

*0.5 MH is a typical starting point for the Common Mode Line Filters. By increasing or decreasing the value of L you can set the drain current to a minimum to meet your application’s requirements.

Figure 2.3.8: Motor Cableing Greater than 50 Feet

Recommended Motor Cable AWG Sizes

MForce PowerDrive Recommended Motor Cable AWG

1 Amperes (Peak)

Length (Feet)

 

10

25

50*

75*

100*

 

 

 

 

 

 

 

Minimum AWG

 

20

20

18

18

16

 

2 Amperes (Peak)

 

 

 

 

 

 

 

 

Length (Feet)

 

10

25

50*

75*

100*

Minimum AWG

 

20

18

16

14

14

 

 

 

 

 

 

 

 

3 Amperes (Peak)

 

 

 

 

 

 

 

 

Length (Feet)

 

10

25

50*

75*

100*

 

 

 

 

 

 

 

Minimum AWG

 

18

16

14

12

12

 

 

 

 

 

 

 

 

4 Amperes (Peak)

 

 

 

 

 

 

 

 

Length (Feet)

 

10

25

50*

75*

100*

Minimum AWG

 

18

16

14

12

12

 

 

 

 

 

 

 

5 Amperes (Peak)

Length (Feet)

10

25

50*

75*

100*

 

 

 

 

 

 

Minimum AWG

16

16

14

12

12

 

6 Amperes (Peak)

 

 

 

 

 

 

 

 

Length (Feet)

10

25

50*

75*

100*

Minimum AWG

14

14

14

12

12

 

 

 

 

 

 

 

7 Amperes (Peak)

 

 

 

 

 

 

 

 

Length (Feet)

10

25

50*

75*

100*

 

 

 

 

 

 

Minimum AWG

12

12

12

12

12

 

 

 

 

 

 

*Use the alternative methods illustrated in example B when cable length is ≥ 50 feet. Also, use the same current rating when the alternate AC power is used.

Table 2.3.1: Recommended Wire Gauges

Part 2: Interfacing and Configuring

17

Page 37
Image 37
Intelligent Motion Systems Motion Detector Example B Motor Cabling Greater Than 50 Feet, Recommended Motor Cable AWG Sizes