Manuals
/
Intelligent Motion Systems
/
Computer Equipment
/
Computer Hardware
Intelligent Motion Systems
user manual UDAS-1001E Series Hardware User Manual, for the
Models:
UDAS-1001E
1
1
65
65
Download
65 pages
26.36 Kb
1
2
3
4
5
6
7
8
<
>
Troubleshooting
Specs
Install
Connecting the UDAS Unit
Diagnostic
Signal Name
Adjust Input Offset Voltage
Setting the Configuration
Power Test
Accessories
Page 1
Image 1
INNOVATIVE PC Data Acquisition Solutions
UDAS-1001E
Series
Hardware User Manual
for the
Multifunction Data Acquisition System
855M495 1.0
Page 2
Page 1
Image 1
Page 2
Contents
INNOVATIVE PC Data Acquisition Solutions
UDAS-1001E Series Hardware User Manual
Multifunction Data Acquisition System
for the
General
Warranty and Repair Policy Statement
Static Sensitivity
Technical Assistance and Service
Online Support
Email Support
Use of Equipment
Trademarks
FCC Radio Frequency Interference Statement
Revision History
UDAS-1001E Series User Manual
Version
Date
UDAS-1001E Series Data Acquisition Systems
Configuration and Installation
Checking the System
Table of Contents
Accessories
Specifications
Appendix C Analog Input and Output Calibration Procedures
Appendix A
Chapter
UDAS-1001E Series Data Acquisition Systems
1.1 Introduction
UDAS-1001E-1
SoftwareSupport Library
1.1.1 Features
Analog Output
Analog Input
UDAS SYSCHECK
U-Link Software Libraries for Windows
1.2.1 Data Acquisition Functions
1.2 UDAS 1001E Series Functional Description
Digital Input/Output
Counter
Starting and Stopping the High-Speed Analog Input Mode
High-Speed Analog Input Mode
Starting Conversions
Channel Scanner
Rate Generator
Stopping Conversions
channel 5 channel 6 channel 7 channel 0 channel
High-Speed Analog Input Triggering
channel 7 channel
Digital I/O
Auto Zero
Example
Analog Output
Digital I/O signals are TTL-compatible and perform functions such as reading digital inputs, driving digital outputs, and detecting input change-of-state
Counters
Termination
1.520
FIGURE 1.2 UDAS-1001E-4 dimensional drawing
5.750 6.600
7.290
1.2.2 Power
1.3 Software Support and Accessories
Diagnostic
1.3.1 Software Support
LabVIEW UDAS Support Library
Visual Designer UDAS Support Library
2.2 Power-on Default Digital I/O Configuration
Configuration and Installation
2.1 Introduction
Removing the Cover
FIGURE 2.1 UDAS Switch S1
Setting the Configuration
Enabling the CJC
Reinstalling the Cover
JP1 Jumper Position
Differential
JP2 Jumper Position
TABLE 2.1 CJC Jumper Positions
Making the Initial Connection
2.3 Connecting the UDAS Unit
3.1 Introduction
Chapter 3 Checking the System
Installing SYSCHECK
3.2 Installing and Running UDAS SYSCHECK
Use your CD drive letter\Syscheck\SETUP.EXEENTER
3.3 SYSCHECK Operation
FIGURE 3.1 Unit Info dialog
3.3.1 Unit Info
FIGURE 3.2 UDAS SYSCHECK System Check dialog
3.3.2 System Check
FIGURE 3.3 UDAS SYSCHECK Analog Input Test of a UDAS unit
3.3.2.1 Analog Input Test
FIGURE 3.4 UDAS SYSCHECK Analog Output Test of a UDAS unit
3.3.2.2 Analog Output Test
FIGURE 3.5 UDAS SYSCHECK Counter Test in Count Mode
3.3.2.3 Counter Test
The status field is looking for TTL transitions
FIGURE 3.7 UDAS SYSCHECK Counter Test Measure Frequency Mode
Digital I/O Test
3.3.3 Paced Analog Input
FIGURE 3.10 High-Speed Aquisition Sample
3.4.1 Basic Troubleshooting
3.4 Troubleshooting Tips
3.4.1.1 Verify Lower Level Drivers
USB Port
Troubleshooting Errors
Power Test
UDAS Drivers
Check the wiring and cables for shorts or damage
A.1 UDAS-1001E Series Hardware Specifications
Specifications
SPECIFICATION
TABLE A.1 Hardware Specifications
SPECIFICATION
TABLE A.1 Hardware Specifications Continued
Specifications
PARAMETER
TABLE A.1 Hardware Specifications Continued
SPECIFICATION
PARAMETER
CONDITIONS
FIGURE A.1 Dimensions of the UDAS unit Top view
A.2 UDAS-1001E-3, UDAS-1001E-4 Dimensions
FIGURE A.2 Dimensions of the UDAS unit Rear panel
4.700 525
FIGURE A.3 Dimensions of the UDAS unit Bottom view
1.295
4.700
MAXIMUM COMPONENT HEIGHT
FIGURE A.4 Dimensional Drawing of the UDAS series PCB
5.305
4.70
Signal Name
A.3 UDAS I/O Connectors
TABLE A.2 UDAS I/O Connectors
Single Ended Input Function
Signal Name
A.2 UDAS I/O Connectors Continued
Single Ended Input Function
Differential Input
A.2 UDAS I/O Connectors Continued
Signal Name
Single Ended Input Function
Differential Input
TABLE B.1 Accessories for the UDAS-1001E Series
Accessories
Appendix B
B.1.1 PCI-20429T-1 Multifunction Termination Panel
B.1 UDAS Termination Panels
FIGURE B.2 PCI-20429T-1 Multifunction Termination Panel
FIGURE B.3 UDAS-1001E Termination Options
B.1.2 UDAS Termination and Signal Conditioning Options
FIGURE B.4 UDAS-1001E Termination Options continued
I/O Connectors
To UDAS unit
Analog In Single-Ended and Differential Function
FIGURE B.5 Diagram of the PCI-20430A-1’s connectors and cables
Analog
Analog In Single
B.1.3 Isolator Blocks
Summary of Features
PCI-1100 Series Digital Opto-Isolator Blocks
C.1 UDAS Analog Input Circuit Calibration Procedures
Appendix C Analog Input and Output Calibration Procedures
C.1.1 Removing the UDAS Unit’s Cover
Equipment Required
FIGURE C.1 Locations of Potentiometers for Adjusting Analog Circuits
Analog Input and Output Calibration Procedures
TP21 R24 R25 R26 R36
TP27
Adjust Offset and Gain for ±10Volt Input Range
C.1.2 Analog Input Calibration Procedure
Adjust Input Offset Voltage
Adjust Offset and Gain for ± 5Volt Input Range
Adjust Offset and Gain for 0 to 10 Volt Range
Equipment Required
C.2 UDAS Analog Output Circuit Calibration Procedure
Analog Output Channel 1 Offset and Gain
Analog Output Channel 0 Offset and Gain
Index
F features
G gate
U UDAS