Chapter 3 Checking the System

Chapter 3 Checking the System

3.1 Introduction

This chapter contains instructions for installing and using the UDAS SYSCHECK software. The software contains diagnostic features that verify the UDAS unit is functioning.

WARNING!

Use extreme caution when using SYSCHECK.

The UDAS SYSCHECK software could cause unexpected results in the equipment that you connect to the UDAS unit.

Depending on the type of equipment that you have connected to the UDAS unit, severe damage to equipment and/or bodily harm may occur while conditions of the UDAS are in transition.

Large unisolated voltages may damage the UDAS unit. UDAS analog output will not drive low impedance loads.

The UDAS digital I/O inputs and outputs must be TTL compliant.

UDAS analog inputs in excess of 20 V may cause permanent damage to the UDAS unit. UDAS counter inputs must be TTL compliant.

SYSCHECK is only an interface to the UDAS unit(s). The way that you interface input or outputs to the UDAS can be a complicated issue.

Since a variety of termination panels are available for the UDAS units, refer to the documentation provided with the termination panel for the exact I/O configuration of the specific panel that you purchased.

Termination options are discussed in Appendix B, Accessories in this manual.