4221 Condor Hardware Installation Procedures
Board Status LEDsLEDs 1, 2, 3, and 4 are Board Status LEDs which provide the following functions:
•Power On Self Test (POST) Mode
•Monitor Mode
•Run Mode
POST Mode: This mode provides diagnostics for the CPU and Buffer. Refer to the following table for a list of diagnostics performed while in this mode:
Table
Hex Code | Diagnostic | Definition | Type of Test |
|
|
|
|
|
|
|
|
0x01 | CPU Register Test | CPUFAIL | CPU Core Test |
|
|
|
|
0x02 | ROM Checksum | ROMFAIL | CPU Core Test |
|
|
|
|
0x03 | Walking 1’s SRAM | STAT1FAIL | CPU Core Test |
|
|
|
|
0x04 | Walking 0’s SRAM | STAT0FAIL | CPU Core Test |
|
|
|
|
0x05 | Decrementing Longwords | STATLFAIL | CPU Core Test |
|
|
|
|
0x06 | Word Access | STATWFAIL | CPU Core Test |
|
|
|
|
0x07 | Byte Access | STATBFAIL | CPU Core Test |
|
|
|
|
0x08 | Reserved | RESERVED | CPU Core Test |
|
|
|
|
0x09 | Walking 1’s In Buffer | BUFFERFAIL1 | Static Buffer Test |
|
|
|
|
0x0A | Walking 0’s In Buffer | BUFFERFAIL0 | Static Buffer Test |
|
|
|
|
0x0B | Decrementing Longwords | BUFFERFAIL | Static Buffer Test |
|
|
|
|
0x0C | Walking 1’s, 0’s VME DMA | VMEFAIL | Control Register Access |
|
|
|
|
0x0D | Motherboard FEC Tests | FEC0 & 1 | Control Register Access |
|
|
|
|
0x0E | Daughter Card FEC Tests | FEC2 & 3 | Control Register Access |
|
|
|
|
Monitor Mode: In this mode, LEDs will sequentially flicker when Serial Port A is active and the onboard monitor is controlling the Condor.
Run Mode: When in this mode, the Condor is accepting commands from the host. Refer to the following table for a list of LED definitions while in this mode:
15