4221 Condor Hardware Installation Procedures
Board Status LEDsLEDs 1, 2, 3, and 4 are Board Status LEDs which provide the following functions:
•Power On Self Test (POST) Mode
•Monitor Mode
•Run Mode
POST Mode: This mode provides diagnostics for the CPU and Buffer. Refer to the following table for a list of diagnostics performed while in this mode:
Table 
| Hex Code | Diagnostic | Definition | Type of Test | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
0x01  | CPU Register Test  | CPUFAIL  | CPU Core Test  | 
  | 
  | 
  | 
  | 
0x02  | ROM Checksum  | ROMFAIL  | CPU Core Test  | 
  | 
  | 
  | 
  | 
0x03  | Walking 1’s SRAM  | STAT1FAIL  | CPU Core Test  | 
  | 
  | 
  | 
  | 
0x04  | Walking 0’s SRAM  | STAT0FAIL  | CPU Core Test  | 
  | 
  | 
  | 
  | 
0x05  | Decrementing Longwords  | STATLFAIL  | CPU Core Test  | 
  | 
  | 
  | 
  | 
0x06  | Word Access  | STATWFAIL  | CPU Core Test  | 
  | 
  | 
  | 
  | 
0x07  | Byte Access  | STATBFAIL  | CPU Core Test  | 
  | 
  | 
  | 
  | 
0x08  | Reserved  | RESERVED  | CPU Core Test  | 
  | 
  | 
  | 
  | 
0x09  | Walking 1’s In Buffer  | BUFFERFAIL1  | Static Buffer Test  | 
  | 
  | 
  | 
  | 
0x0A  | Walking 0’s In Buffer  | BUFFERFAIL0  | Static Buffer Test  | 
  | 
  | 
  | 
  | 
0x0B  | Decrementing Longwords  | BUFFERFAIL  | Static Buffer Test  | 
  | 
  | 
  | 
  | 
0x0C  | Walking 1’s, 0’s VME DMA  | VMEFAIL  | Control Register Access  | 
  | 
  | 
  | 
  | 
0x0D  | Motherboard FEC Tests  | FEC0 & 1  | Control Register Access  | 
  | 
  | 
  | 
  | 
0x0E  | Daughter Card FEC Tests  | FEC2 & 3  | Control Register Access  | 
  | 
  | 
  | 
  | 
Monitor Mode: In this mode, LEDs will sequentially flicker when Serial Port A is active and the onboard monitor is controlling the Condor.
Run Mode: When in this mode, the Condor is accepting commands from the host. Refer to the following table for a list of LED definitions while in this mode:
15