Chapter 3 - MACSI Host Interface
Command Options
Table
Command Options
Offst | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0x01 | PFM |
|
|
|
|
| RUD | RFD |
|
| Port |
|
| RMC | UUD | IE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Interrupt enable (IE)
As defined in the Common IOPB Structures.
Update user default (UUD)
Setting this bit updates the
Restore manufacturer’s address (RMC)
This field restores the original manufacturer’s MAC address, using information stored in the CIB.
Port selector
This field determines the port to which the action will be applied. Permitted values range from 0 to 3.
Restore factory default (RFD)
Setting this bit restores the current address from the factory assigned default stored in NVRAM. This action eliminates any currently stored user default for the specified port.
Restore user default data (RUD)
Setting this bit restores the current address from the user data stored in the CIB.
Program factory MAC address (PFM)
Setting this bit updates the factory assigned default address stored in NVRAM from the contents of the Physical Node Address field. This bit is intended only for internal Interphase use, and should not be documented or used externally.
86