SECTION 4—SAFETY INSPECTION/TROUBLESHOOTING

Inspect and clean the stability lock gears. Replace if worn.

Clean upholstery and armrests.

Inspect charger AC power cord for damage. Replace if necessary.

Check that wiring is routed and secured properly to ensure that wiring does NOT become entangled and damaged.

Inspect electrical components for signs of corrosion. Replace if corroded or damaged.

Check that all labels are present and legible. Replace if necessary.

Ensure casters are free of debris.

Troubleshooting - Mechanical

WHEELCHAIRVEERS LEFT/RIGHT

SLUGGISH TURN/ PERFORMANCE

CASTERS FLUTTER

SQUEAKSAND RATTLES

LOOSENESS WHEELCHAIRIN

WHEELCHAIR3 WHEELS

SOLUTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

X

X

X

 

 

 

If pneumatic, check tires for correct and equal pressure.

 

 

 

 

 

 

 

X

X

X

X

 

 

Check for loose stem nuts/bolts.

 

 

 

 

 

 

 

X

 

X

 

 

 

Check that casters contact ground at the same time.

 

 

 

 

 

 

 

Troubleshooting - Electrical

NOTE: For additional troubleshooting information and explanation of error codes, refer to the individual Electronics Manual supplied with each wheelchair

SPJ+, SPJ+ w/PSS or SPJ+ w/ACC Joysticks

The joystick information gauge and the service indicator give indications of the type of fault or error detected by the control module. When a fault is detected, the wheelchair may stop and not drive. The LEDs on the information gauge may flash in a particular pattern or the service indicator light will flash. The number or type of flashes indicates the nature of the error. If multiple errors are found, only the first error encountered by the control module will be displayed.