Invacare X-Terminator BB, 1114851 manual Course Adjustment, NOTE Rear wheels are removed from the

Models: Terminator BB

1 76
Download 76 pages 7.71 Kb
Page 44
Image 44
Course Adjustment

SECTION 5—WHEELS

A4 Camber System

Course Adjustment

NOTE: For this procedure, refer to FIGURE 5.10.

NOTE: This procedure is required any time the axle tube is moved from the factory set position or is replaced.

NOTE: Make the following adjustment for one camber at a time.

1.Open the camber clamps. Refer to Opening/Closing Camber Clamps on page 39.

2.Loosen the phillips screws that secure the adjustment rings to the axle tube.

3.Slowly rotate the axle tube until the rear wheels are approximately in a straight line.

WARNING

QUICK RELEASE LEVERS - Make sure the quick release levers are pointing towards the rear of the wheelchair and are in the closed position before using the wheelchair, otherwise personal injury or damage to the wheelchair may occur.

WARNING

STANDARD AND SUSPENSION CAMBER CLAMPS - Make sure the hex screws are securely tightened before using the wheelchair, otherwise personal injury or damage to the wheelchair may occur.

4.Close the camber clamp. Refer to Opening/Closing Camber Clamps on page 39.

5.Measure the distance between the center lines at the rear and front of the rear wheels at approximately 12 inches from the ground/floor. Refer to Determining Toe In/Toe Out on page 42.

6.Repeat STEPS 1‐4 until the toe in/toe out measurement is less than 1/2‐inch (0 + 1/4‐inch for maximum rollability).

7.Rotate either the right or left adjustment ring until the stop on the ring is at the top of the slot in the camber clamp as shown in FIGURE 5.10 and securely tighten the phillips screw on the positioned adjustment ring.

NOTE: Rear wheels are removed from the

Axle Tube - Rotates Up and Down

drawings for clarity. There is no need to remove rear wheels from the wheelchair during adjustment.

NOTE: FIGURE 5.10 shows two examples of how the adjustment rings can be positioned.

Everyday and Sport Series Wheelchairs

44

Part No 1114851

Page 44
Image 44
Invacare X-Terminator BB Course Adjustment, NOTE Make the following adjustment for one camber at a time, A4 Camber System