(Cross flow <Caution at reassembling>

No. Part name

Procedures

Remarks

(Cross flow <Caution at reassembling>

fan

a) At assembling work of the bearing base, check

 

that the drain pipe is surely incorporated

 

in the back body.

 

(Otherwise, water leak is caused.)

 

Drain pipe

Bearing base

b) To incorporate the fan motor, remove the fan

 

motor rubber (at shaft core side), incorporate the

 

motor into the position in the following figure,

 

and then install the fan motor.

 

• Install the cross flow fan so that the right end

 

of the 1st joint from the right of the cross flow

 

fan is set keeping 70.5mm from wall of rear

 

plate of the main unit.

 

• Holding the set screw, install the cross flow

 

fan so that U-groove of the fan motor comes to

Joint

 

the mounting hole of the set screw.

U groove

 

• Perform positioning of the fan motor as fol-

70.5mm

lows:

 

When assembling the fan motor, the fan motor must be installed in such a way that the fan motor leads will be taken out is positioned at the bottom front.

After assembling the two hooking claws of the motor band (right) into the main body, position the fan motor, insert it, and then secure the motor band (right) using the two fixing screws.