9-6. Hi-POWER Mode

([Hi-POWER] button on the remote controller is pushed.)

When [Hi-POWER] button is pushed while the indoor unit is in Auto, Cooling or Heating operation, Hi-POWER mark is indicated on the display of the remote controller and the unit operates as follows.

(1)Automatic operation

The indoor unit operates in according to the current operation.

(2)Cooling operation

The preset temperature drops 1°C.

(The value of the preset temperature on the remote controller does not change.)

If the difference between the preset tempera- ture and the room temperature is big, the horizontal louver moves to the Hi-POWER position automatically. Then when the differ- ence between them gets smaller, the horizon- tal louver returns automatically.

(3)Heating operation

The preset temperature increases 2°C.

(The value of the preset temperature on the remote controller does not change.)

(4)The Hi-POWER mode can not be set in Dry operation