Toshiba RAS-M16EKCVP-E, RAS-M13EKCVP-E, RAS-M18EACV-E, RAS-M14EACV-E, RAS-M18EAV-E Outdoor Unit, 111

Models: RAS-B10EKVP-E RAS-M14EAV-E RAS-B13EKVP-E RAS-M18EAV-E RAS-M10EKCVP-E RAS-M16EKCVP-E RAS-M14EACV-E RAS-M18EACV-E RAS-M13EKCVP-E

1 136
Download 136 pages 38.01 Kb
Page 111
Image 111
12-3. Outdoor Unit

12-3. Outdoor Unit

No.

Part name

 

Procedures

Remarks

! Common

1.

Detachment

Upper cabinet

 

procedure

 

 

 

 

NOTE :

 

 

 

 

 

 

Water proof cover

 

 

 

Wear gloves for this job.

 

 

 

 

 

 

 

 

 

Otherwise, you may injure your hands on

 

 

 

 

 

the parts, etc.

 

 

 

 

1)

Stop operation of the air conditioner, and turn off

 

 

 

 

 

the main switch of the breaker for air condi-

 

 

 

 

 

tioner.

 

 

 

 

2)

Remove the valve cover. (ST1TØ4 x 8l 1 pc.)

 

 

 

 

 

• After removing screw, remove the valve cover

 

 

 

 

 

pulling it downward.

 

 

 

 

3)

Remove wiring cover (ST1TØ4 x 8l 2 pcs.), and

Valve cover

 

 

 

then remove connecting cable.

 

 

 

 

4)

Remove the upper cabinet.

 

 

 

 

 

(ST1TØ4 x 8l 5 pcs.)

 

 

 

 

 

• After removing screws, remove the upper

 

 

 

 

 

cabinet pulling it upward.

 

 

 

 

2.

Attachment

Insert the bent part into the rear

 

 

1)

Attach the water-proof cover.

panel of the inverter

Bring into

 

 

 

contact

 

 

 

 

 

against

 

 

 

NOTE :

 

these parts

 

 

 

 

 

 

 

 

The water-proof cover must be attached

 

 

 

 

 

without fail in order to prevent rain water,

 

 

 

 

 

etc. from entering inside the indoor unit.

 

 

 

 

2)

Attach the upper cabinet.

Align the stitch

Bend downward,

 

 

 

(ST1TØ4 x 8l 5 pcs.)

line with the top

and align with

 

 

 

edge of the

the inside surface of

 

 

3)

Perform cabling of connecting cable, and attach

front cabinet

the front cabinet

 

 

How to mount the water-proof cover

 

 

 

the wiring cover.

 

 

 

 

 

Place the wiring cover over the opening used to work on the connecting wires of the side

cabinet, and secure it using the two fixing screws (ST1TØ4 x 8l 2 pcs.). At this point, the top cushion of the wiring cover must be on the inside of the opening.

4)Attach the valve cover. (ST1TØ4 x 8l 1 pc.)

Insert the upper part into the square hole of the side cabinet, set hook claw of the valve cover to square holes (at three positions) of the main unit, and attach it pushing upward.

– 111 –

Page 111
Image 111
Toshiba RAS-M16EKCVP-E, RAS-M13EKCVP-E, RAS-M18EACV-E, RAS-M14EACV-E, RAS-M10EKCVP-E, RAS-M18EAV-E Outdoor Unit, 111