Draining the water

CAUTION

1.Install the outdoor unit without anything blocking the discharging air.

2.When the outdoor unit is installed in a place always exposed to strong winds like on the coast or on a high story of a building, secure the normal fan operation using a duct or a wind shield.

3.Especially in windy areas, install the unit to prevent the admission of wind.

4.Installation in the following places may result in trouble. Do not install the unit in such places.

A place full of machine oil.

A saline-place such as the coast.

A place full of sulfide gas.

A place where high-frequency waves are likely to be generated, such

as from audio equipment, welders, and medical equipment.

Strong wind

Draining the water

• Holes are provided on the base plate of the outdoor unit to ensure that the defrost water produced during heating operations is drained off efficiently. If a centralized drain is required when installing the unit on a balcony or wall, follow the steps below to drain off the water.

1.Proceed with water-proofing by installing the water-proof rubber caps d in the 2 elongated holes on the base plate of the outdoor unit.

[How to install the water-proof rubber caps]

1)Place four fingers into each cap, and insert the caps into the water drain holes by pushing them into place from the underside of the base plate.

2)Press down on the outer circumferences of the caps to ensure that they have been inserted tightly.

(Water leaks may result if the caps have not been inserted properly, if their outer circumferences lift up or the caps catch on or wedge against something.)

2.Install the drain nipple c and a commercially available drain hose (with 16 mm inside diameter), and drain off the water.

(For the position where the drain nipple c is installed, refer to the installation diagram of the indoor and outdoor units.)

Check that the outdoor unit is horizontal, and route the drain hose at a downward sloped angle while ensuring that it is connected tautly.

Base plate

d Water-proof rubber caps (supplied with the outdoor unit)

Base plate

c Drain nipple

c Drain nipple

Commercially available drain hose

Do not use ordinary garden hose, which can flatten and prevent water from draining.