Toshiba RAS-M14EAV-E, RAS-M13EKCVP-E Outdoor Unit, 25, Parts name, Model name, Rating

Models: RAS-B10EKVP-E RAS-M14EAV-E RAS-B13EKVP-E RAS-M18EAV-E RAS-M10EKCVP-E RAS-M16EKCVP-E RAS-M14EACV-E RAS-M18EACV-E RAS-M13EKCVP-E

1 136
Download 136 pages 38.01 Kb
Page 25
Image 25

6-2. Outdoor Unit

RAS-M14EAV-E, RAS-M14EACV-E, RAS-M18EAV-E, RAS-M18EACV-E

*1

*1

No.

Parts name

Model name

Rating

 

 

 

 

 

SC coil (Noise filter) (L03)

ADR2520-R15TB or SC-20-01J-A

AC 250V, 20A, 0.15mH

1

 

 

 

SC coil (Noise filter) (L01)

ADR25H-200R8TB

AC 250V, 20A, 0.88mH

 

 

 

 

 

2

DC-DC transformer

SWT-72 or SWT-83

Primary side DC 280VSecondary side:

 

 

7.5V x 1, 13V x 126.5V x 3, 16V x 1, 15V x 1

 

 

 

 

 

 

 

3

Outside fan motor

ICF-140-43-4

DC 140V, 43W

 

 

 

 

4

Relay (4-way valve)

G5N-1A

Coil: DC 12V, Contact: 2A, AC250V

 

 

 

 

5

Relay (Power relay)

DI12D1-O or G4A-1A-PE

Coil: DC 12V, Contact: 20A, AC250V

 

 

 

 

6

Discharge temp. sensor (TD-sensor)

(Inverter attached)

64k(20°C)

 

 

 

 

7

Outside air temp. sensor

(Inverter attached)

10k(25°C)

(TO-sensor)

 

 

 

 

 

 

 

 

 

8

TGa-sensor (Heat pump models)

(Inverter attached)

64k(25°C)

 

 

 

 

9

TGb-sensor (Heat pump models)

(Inverter attached)

64k(25°C)

 

 

 

 

10

TGa-sensor (Cooling-only models)

(Inverter attached)

10k(25°C)

 

 

 

 

11

TGb-sensor (Cooling-only models)

(Inverter attached)

10k(25°C)

 

 

 

 

12

Evaporator temp. sensor

(Inverter attached)

10k(25°C)

(TE-sensor)

 

 

 

 

 

 

 

 

 

13

Suction temp. sensor (TS-sensor)

(Inverter attached)

10k(25°C)

 

 

 

 

14

Terminal block (9P)

20A, AC 250V

 

 

 

 

 

 

For protection of switching power source (F03)

3.15A, AC 250V

 

 

 

 

15

Fuse

For protection of inverter input overcurrent

25A, AC 25V

 

 

 

 

 

 

For protection of power source

6.3A, AC 250V

 

 

 

 

16

Electrolytic capacitor

LLQ2G761KHU

DC 400V, 760F

 

 

 

 

17

IGBT (Q200~Q205)

GT20J321

600V, 20A

 

 

 

 

18

Compressor (M18)

DA130A1F-25F

3 phases, 4 poles, 1,100W

 

 

 

 

19

Compressor (M14)

DA111A1F-20F1

3 phases, 4 poles, 750W

 

 

 

 

20

Compressor thermo.

US622KXTMQO

OFF: 125±4°C, ON: 90±5°C

 

 

 

 

21

Rectifier (DB01, DB02)

D25 X B60

Diode: 600V, 25A

 

 

 

 

22

IGBT (Q404)

GT40Q321 or GT30J121

IGBT: 600V, 40A

 

 

 

 

23

Reactor (Main)

CH-57

L = 10mH, 16A

 

 

 

 

24

Reactor (Sub)

CH-43-Z-K

L = 10mH, 1A

 

 

 

 

NOTE: *1 Heat pump models only.