10. INSTALLATION PROCEDURE

10. INSTALLATION PROCEDURE

10-1.Installation Diagram of Indoor and Outdoor Units

Hook

140 mm or more

47 mm or more

Hook a Installation plate

74 mm or more

For the rear left and left piping

Wall

Insert the cushion between

Hook

– 60 –g Mounting screw

the indoor unit and wall, and tilt the indoor unit for better installation work.

Do not allow the drain hose to become slack.

eZeolite-plus filter

Manual backgroundfPlasma pure filter

ZShield pipe (for extension drain hose)

Cut the piping hole slightly sloped

Make sure the drain hose is sloped downward.

bWireless remote control

Air filters

 

Y

The auxiliary piping can be connected at the left, rear left, rear right, right, bottom

dRemote control holder (Mounting holes on both left and right sides)

80 mm or more only when unobstructed to the front and both sides

right or bottom left as shown below.

hRemote control

holder mounting screw

(C)

100 mm or more from wall

In principle, leave open

50 mm or more from wall

(D)

As shown in the figure, position power cord and connecting cable downward, and lead out along

Right

Rear

Before installing the wireless remote control

With the remote control cover removed, correctly load the supplied batteries while observing their

polarity.

bWireless remote control

Cover

cBatteries

200 mm or more

(B)

When installing the outdoor unit, leave open in at least two of directions (A), (B), (C) and (D) shown in the right figure.

Ensure sufficient space to allow drainage

piping connection port.

(A)

250 mm or more from wall

power cord

Extension drain hose (Option: RB–821SW)

right

Rear left

Left

Bottom right

Bottom left

Insulate the refrigerant pipes separately, not together.

6 mm thick heat resisting polyethylene foam

In case the piping is installed above the ceiling, it shall be covered with thicker insulating material (polyethylene form, 10 mm-thick)