12. Air

This function generates nagative ion while cleaning the

 

Operation button

purifying

air in the room.

 

Present

 

 

control

If air purifier-ON signal is received while the air condi-

PURE button

Air conditioner

status

 

 

 

 

tioner stops, the air purifier starts operation, and if it is

Stop

Air purifier

AC operation*

 

received while the air conditioner operates, the air

 

 

 

 

 

conditioner and the air purifier start operation.

Air purifier only

Stop (All)

AC + Air purifier

 

The air ion generator operates linked with the air

Air conditioner

AC + Air purifier

All stop

 

purifying operation.

 

 

 

 

 

 

Joint use of AC

AC operation

All stop

 

 

and air purifier

 

 

 

 

 

 

 

Sending air purifier-ON

 

* When the previous operation was the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

operation of air conditioner + air purifier,

1

,

2

 

 

an operation of air conditioner + air

 

 

purifier starts by pushing AC button on

1

 

2

 

the remote controller.

 

 

Air conditioner stops

 

 

Air conditioner operates

 

 

 

 

 

 

(Operation of air conditioner + air

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

purifier is stored in memory.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPERATION indicator ON

 

 

Start of air purifier-ON

 

 

 

 

 

 

 

 

 

*1

 

 

 

 

 

 

 

Louver*1

Fan speed *2

 

 

 

 

 

 

 

 

 

 

 

 

 

Memory position

 

 

Air conditioner +

 

 

Air purifying

Cooling position

AUTO, L, L+, M,

 

of louver/COOL

 

 

air purifier operate

 

 

operation

 

M+, H

 

 

 

 

 

Follows to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*2

 

 

 

 

 

AC + Air purifying

AC operation

Follows to

 

 

 

 

 

 

Fan ON

 

 

 

 

 

 

operation

 

AC operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1

Swing is available

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air purifier ON

 

 

 

 

*2

Fan speed is Fan Auto mode varies in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

order, (M + 1) (L) (L–) (SL).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air purifying operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sending air purifier-OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

,

4

 

 

 

 

 

 

 

3

 

4

 

 

 

 

 

 

Air purifier operates

 

 

Air conditioner +

 

 

 

 

 

 

 

 

 

 

 

 

Air purifier operate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPERATION indicator OFF

 

 

Filter-OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan stop

 

 

Air conditioner operates

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air purifier-OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Louver close

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All stop

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 