Item | Operation flow and applicable data, etc. | Description | ||||
12. Air |
|
|
|
|
| 1. Purpose |
|
|
|
|
| The air purifying control function is to alert | |
purifying |
| Purifying operation |
|
|
| |
control |
|
|
|
| the user to trouble in the ionizing or air | |
[Detection |
|
|
|
|
| purifying operation. |
of abnor- |
| Total |
|
|
| 2. Description |
mality] | YES |
|
|
| ||
|
| operation time |
|
|
| Trouble is determined to have occurred |
|
| 1000H |
|
|
| |
|
|
|
|
| (indicated by the FILTER indicator) in the | |
|
| NO |
|
|
| |
|
|
|
|
| following four cases. | |
| FILTER indicator ON |
|
|
| ||
|
|
| NO |
|
| 1) When a count of 1000H has been |
|
| Error input |
|
| reached on the timer | |
|
|
|
|
| ||
|
| YES |
|
|
| 2) When the panel switch has been set to |
| Purifier power OFF |
|
|
| OFF by the opening of the air inlet grile, | |
|
|
|
|
|
| |
|
| Purifier power ON | NO | FILTER |
| etc. |
|
|
| 3) When an abnormal discharge caused | |||
|
| 1 minute or less |
| continues. |
| |
|
| YES |
|
|
| by a symptom such as the |
|
|
|
|
| dirt has been detected while the air | |
|
| FILTER indicator ON |
| Purifier power OFF |
| |
|
|
|
| purifier is ON | ||
|
|
|
|
|
| |
|
|
|
|
|
| 4) When the electric dust collector has not |
|
| Purifier power OFF |
| Error detection | NO | been installed correctly |
|
|
| Approx. 10 minutes | * Trouble case (2) or (3) is deemed to | ||
|
|
|
| passed. |
| |
|
|
|
|
| have occurred when the action | |
|
|
|
| YES |
| |
|
|
|
|
| concerned continues for more than | |
|
|
|
|
|
| |
|
|
|
| Purifier power ON |
| one second. |
|
|
|
| Error input | NO | 3. Operation |
|
|
|
|
| The sequence that FILTER indicator is | |
|
|
|
| YES |
| |
|
|
|
|
| turned on are described in the left flow- | |
|
|
|
|
|
| |
|
|
|
|
|
| chart. |
| 1 | 2 |
| 3 |
| ! When 1000H timer counts up, the |
|
|
|
|
|
| FILTER indicator keeps lighting even if |
|
|
|
|
|
| the operation is stopped by the remote |
| 1) Reset by RESET button. |
|
|
| controller. | |
| 2) Reset by RESET button or by the stop direction from | The timer is stored in memory of the | ||||
| microcomputer, and the operation time | |||||
| the remote controller. |
|
|
| ||
|
|
|
| is cleared by filter RESET button on the | ||
| * When the breaker is turned [ON] (In restart time | |||||
| indoor unit or a power failure. (FILTER | |||||
| after power failure) or RESET button is pushed |
| ||||
|
| indicator goes off.) | ||||
| while the FILTER indicator is turned on, the air |
| ||||
|
| " A trouble detected within 1 minute after | ||||
| purifier is not turned on until the integrated opera- | |||||
| activation of the air is immediately | |||||
| tion time of the indoor fan exceeds 1 hour after |
| ||||
|
| judged as an error and the FILTER | ||||
| operation start (It is nor the air purifier operation | |||||
| indicator goes on. | |||||
| time). |
|
|
|
| |
|
|
|
|
| # In case that 1 minute passed after | |
| It is the safety measures considering an incomplete | |||||
| drain when electric dust collector has been cleaned | activation of the purifier, the purifier is | ||||
| with water. |
|
|
| turned off while the PURE indicator | |
|
|
|
|
|
| keeps ON. After 10 minutes passed, |
|
|
|
|
|
| restart the purifier and an error is |
|
|
|
|
|
| judged again. |
13. Discharge |
|
| 1. Purpose |
tempera- | Td value | Control operation | This function detects error on the |
ture control | 120˚C | Judges as an error and stops the compressor. | refrigerating cycle or error on the |
| |||
|
| compressor, and performs protective | |
| Reduce the compressor speed. | ||
| 115˚C | control. | |
|
| ||
| Reduce slowly compressor speed. | ||
| 111˚C |
| |
|
| 2. Operation | |
| Keeps the compressor speed. | ||
|
| ||
| 108˚C | • Control of the compressor speed | |
|
| ||
| If the operation is performed with lower speed | ||
|
| The speed control is performed as | |
|
| than one commanded by the serial signal, speed | |
| 101˚C | is slowly raised up to the commanded speed. | described in the left table based upon |
|
| the discharge temperature. | |
| Operates with speed commanded by the serial | ||
|
|
| |
|
| signal. |
|
|
|
|
|