– 113 –

No. Part name

 

Procedure

Remarks

# Inverter

1)

Perform work of item 1 in !.

Inverter cover

assembly

2)

Remove screw (ST1TØ4 x 8l 2 pcs.) of the upper

P. C. board

 

 

part of the front cabinet.

(Soldered surface)

If removing the inverter cover in this condition, P.C. board can be checked.

• If there is no space above the unit, perform work of 1 in ".

Be careful to check the inverter because high-voltage circuit is incorporated in it.

 

 

 

 

Discharging position

Plug of

3) Perform discharging by connecting ,

 

polarity

soldering

 

(Discharging period

 

iron

by discharging resistance (approx. 10040W) or

10 seconds or more)

 

plug of soldering iron to Manual background, Manual background terminals a of the C14 (printed “CAUTION HIGH VOLTAGE” is at- tached.) electrolytic capacitor (760µF) on P.C. board.

 

 

Be careful to discharge the capacitor be-

 

 

 

 

cause the electrolytic capacitor cannot

 

 

 

 

naturally discharge and voltage remains

A screw

 

 

 

according to trouble type in some cases.

(STIT-4X8MSZN)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE :

 

 

 

 

This capacitor is one with mass capacity.

 

 

 

 

Therefore, it is dangerous that a large spark

 

 

 

 

generates if short-circuiting between ,

 

 

 

 

 

 

 

 

 

 

 

polarity with screwdriver, etc. for discharging.

 

 

 

 

 

 

 

 

 

4)

Remove screw (ST1TØ4 x 8l 2 pcs.) fixing the

 

 

 

main body and the inverter box.

Put the compressor

Put each leads

 

 

 

 

 

5) Remove the front cabinet by performing step 1 in

leads and the comp. through the

 

", and remove the fixing screws (ST1TØ4 x 8 l )

thermo leads

slit.

 

through the hole.

 

 

for securing the main body and inverter box.

 

 

 

 

6) Remove various lead wires from the holder at

The connector is

 

 

upper part of the inverter box.

one with lock,

 

7)

Pull the inverter box upward.

so remove it while

 

8)

Disconnect connectors of various lead wires.

pushing the part

 

indicated by an

 

 

 

 

 

 

 

 

 

 

 

 

arrow.

 

 

 

Requirement :

 

 

 

 

 

 

 

As each connector has a lock mechanism,

 

 

 

 

avoid to remove the connector by holding

 

 

 

 

the lead wire, but by holding the connector.

 

 

 

 

 

 

 

 

 

Be sure to remove the connector by holding the connector, not by pulling the lead wire.