In case of right or left piping

In case of right or left piping

• After making slits on the front panel with a knife or similar tool, cut them out with a pair of nippers or an equivalent tool.

Slit

In case of bottom right or bottom left piping

After making slits on the front panel with a knife or similar tool, cut them out with a pair of nippers or an equivalent tool.

Slit

Left-hand connection with piping

Bend the connecting pipes so that they are positioned within 43 mm above the wall surface. If the connecting pipes are positioned more than 43 mm above the wall surface, the indoor unit may be unstable. When bending the connecting pipe, make sure to use a spring bender to avoid crushing the pipe.

Refer to the table below for the bending radius of each connection pipe.

To connect the pipe after installation of the unit (figure)

Outer diameter

Bending radius

6.35 mm

30 mm

 

 

9.52 mm

40 mm

270 mm

(To the front of flare)

Liquid side

12.7 mm

50 mm

170 mm

In case of bottom right or bottom left piping Gas side

43 mm

R30 or less (φ6.3 5), R40 or less (φ9. 52), R50 or less (φ12. 7) Use polishing (polyethylene core or the like for bending pipe).

Outward form of indoor unit

Use a screwdriver handle, etc.

NOTE

If the pipe is incorrectly bent, the indoor unit may be unstable on the wall.

After passing the connecting pipe through the pipe hole, connect the connecting pipe to the auxiliary pipes and wrap the facing tape around them.

CAUTION

Bind the auxiliary pipes (two) and connecting cable with facing tape tightly. In case of leftward piping and rear-leftward piping, bind the auxiliary pipes (two) only with facing tape.

Indoor unit

Auxiliary pipes

Connecting cable

Installation plate

Carefully arrange the pipes so that none of the pipes stick out of the rear plate of the indoor unit.

Carefully connect the auxiliary pipes and connecting pipes to each other and cut off the insulating tape wound on the connecting pipe to avoid double-taping at the joint, moreover, seal the joint with the vinyl tape, etc.

Since condensation can result in machine performance trouble, be sure to insulate both connecting pipes. (Use polyethylene foam as insulating material.)

When bending a pipe, be careful not to crush it.