Mounting the installation plate

Anchor bolt holes

91

mm

 

Pipe hole

Indoor unit

25

mm

 

a Installation plate

Pipe hole

gMounting screw

When the installation plate is directly mounted on the wall

1.Securely fit the installation plate onto the wall by screws with the upper and lower catches, that hold the indoor unit, facing out.

2.To mount the installation plate on a concrete wall use anchor bolts. Drill the anchor bolt holes as illustrated in the above figure.

3.Install the installation plate horizontally and level.

CAUTION

When installing the installation plate with mounting screws, do not use anchor bolt holes. Otherwise the unit may fall down and result in personal injury and property damage.

Anchor bolt

5 mm dia. hole

Projection 15 mm or less – 64 –

g Mounting screw φ4 x 25L

Clip anchor (local parts)

CAUTION

Failure to securely install the unit may result in personal injury and/or property damage if the unit falls.

In case of block, brick, concrete or similar type walls, drill 5 mm dia. holes in the wall.

Insert clip anchors for the g mounting screws.

NOTE

• Install the installation plate using between 4 to 6 mounting screws, being sure to secure all four corners.

Electrical Work

1.The supply voltage must be the same as the rated voltage of the air conditioner.

2.Prepare a power source for the exclusive use of the air conditioner.

NOTE

• Wire type: More than H07RN-F or 245IEC66 (1.0 mm2 or more)