Toshiba RAS-M10EKCVP-E, RAS-M13EKCVP-E 112, Part name, Procedures, Detachment, Attachment

Models: RAS-B10EKVP-E RAS-M14EAV-E RAS-B13EKVP-E RAS-M18EAV-E RAS-M10EKCVP-E RAS-M16EKCVP-E RAS-M14EACV-E RAS-M18EACV-E RAS-M13EKCVP-E

1 136
Download 136 pages 38.01 Kb
Page 112
Image 112
2. Attachment

No.

Part name

Procedures

Remarks

"

Front cabinet 1.

Detachment

 

 

1)

Perform step 1 in 1.

 

 

2)

Remove the fixing screws (ST1TØ4 x 8 l

2 pcs.)

 

 

used to secure the front cabinet and inverter

 

 

cover, the screws (ST1TØ4 x 8 l 3 pcs.) used to

 

 

secure the front cabinet at the bottom plate, and

 

 

the fixing screws (ST1TØ4 x 8l 2 pcs.) used to

 

 

secure the motor base.

 

• The front cabinet is fitted into the side cabinet (left) at the front left side so pull up the top of the front cabinet to remove it.

Front cabinet

2. Attachment

1)Insert the claw on the front left side into the side cabinet (left).

2)Hook the bottom part of the front right side onto

the concave section of the bottom plate. Insert the claw of the side cabinet (right) into the square hole in the front cabinet.

3) Return the screws that were removed above to

 

their original positions, and attach them.

Claw

 

Square hole

Concave section

– 112 –

Page 112
Image 112
Toshiba RAS-M10EKCVP-E, RAS-M13EKCVP-E, RAS-M18EACV-E, RAS-M14EACV-E 112, Part name, Procedures, Detachment, Attachment