Toshiba RAS-M14EAV-E, RAS-M13EKCVP-E, RAS-M18EACV-E, RAS-M14EACV-E Clean operation times

Models: RAS-B10EKVP-E RAS-M14EAV-E RAS-B13EKVP-E RAS-M18EAV-E RAS-M10EKCVP-E RAS-M16EKCVP-E RAS-M14EACV-E RAS-M18EACV-E RAS-M13EKCVP-E

1 136
Download 136 pages 38.01 Kb
Page 52
Image 52

Item

 

Operation flow and applicable data, etc.

Description

 

 

 

 

 

 

 

 

 

 

 

15. Clean

 

 

 

 

 

 

 

 

 

1. Purpose

operation

 

 

 

 

 

 

 

 

 

The clean operation is to minimize

 

 

Unit now performing cooling or

 

 

 

 

 

 

 

 

dry operation

 

 

the growth of mold, bacteria etc. by

 

 

 

 

 

 

 

 

 

 

running the fan and drying so as to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

keep the inside of the air condi-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Push "stop" button

 

 

tioner clean.

 

 

 

 

 

 

 

 

 

 

Clean operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When the cooling or dry operation

 

 

 

Only S.CLEAN indicator lights,

 

 

 

 

and clean operation starts

 

 

shuts down, the unit automatically

 

 

 

 

 

 

 

 

 

 

starts the clean operation which is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

then performed for the specified

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Time set now elapses

 

 

period based on duration of the

 

 

 

 

 

 

 

 

 

 

operation which was performed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

prior to the shutdown, after which

 

 

 

 

 

Operation stops

 

 

 

 

 

 

 

 

 

the clean operation stops. (The

 

 

 

 

 

 

 

 

 

 

clean operation is not performed

 

 

 

 

 

 

 

 

 

 

after a heating operation.)

 

• During clean operations: The louver opens slightly.

2. Operation

 

1) When the stop signal from the

 

 

The indoor fan operates continuously at a speed of

remote controller is received, the

 

 

260 rpm.

 

 

 

 

 

 

S.CLEAN indicator (green) on the

 

 

Clean operation times

 

 

main body lights, and the clean

 

 

 

 

operation starts. (Neither the

 

 

 

 

 

 

 

 

 

 

 

 

Operation mode

 

Operation time

 

Clean operation time

OPERATION indicator nor the

 

 

 

 

TIMER indicator light.)

 

 

 

 

 

 

 

 

 

 

 

 

Cooling:

 

Up to 10 minutes

 

No clean operation

2) The period of the clean operation is

 

 

Auto (cooling)

 

 

 

 

performed (0 minutes)

determined by the duration of the

 

 

Dry

 

 

 

 

 

 

operation performed prior to the

 

 

 

From 10 minutes

 

2 hours

 

 

 

 

 

 

reception of the stop code.

 

 

 

 

 

up to 1 hour

 

 

 

 

 

 

 

 

 

 

 

3) After the clean operation has been

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 hour or longer

 

4 hours

performed for the specified period,

 

 

 

 

 

 

 

 

 

 

the unit stops operating.

 

 

 

 

 

 

 

 

 

Heating:

 

No clean operation performed

 

 

 

Auto (heating)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auto (fan only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shutdown

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• To stop an ongoing clean operation at any time

Press the start/stop button on the remote controller twice during the clean operation. (After pressing the button for the first time, press it for the second time without delay (within 10 minutes).)

– 52 –

Page 52
Image 52
Toshiba RAS-M14EAV-E, RAS-M13EKCVP-E, RAS-M18EACV-E, RAS-M14EACV-E, RAS-M16EKCVP-E, RAS-M10EKCVP-E Clean operation times

RAS-B10EKVP-E, RAS-M14EAV-E, RAS-B13EKVP-E, RAS-M18EAV-E, RAS-M10EKCVP-E specifications

Toshiba is renowned for producing high-quality air conditioning systems that blend performance with energy efficiency. Among its notable offerings are the RAS-M18EACV-E, RAS-M18EAV-E, RAS-B13EKVP-E, RAS-M16EKCVP-E, and RAS-M14EACV-E models. These units cater to various air conditioning needs, providing optimal comfort for residential and light commercial spaces.

The RAS-M18EACV-E and RAS-M18EAV-E models are designed with advanced Inverter technology, which ensures efficient operation by adjusting the compressor speed according to the cooling demand. This feature significantly reduces energy consumption, leading to lower electricity bills while maintaining a consistent indoor temperature. Both units come equipped with a high-capacity cooling system that can efficiently manage even the hottest summer days.

On the other hand, the RAS-B13EKVP-E offers a balance of performance and affordability. It features a compact design ideal for smaller rooms, making it a popular choice for residential applications. This model includes a user-friendly remote control system, allowing for easy temperature adjustments from anywhere in the room.

The RAS-M16EKCVP-E and RAS-M14EACV-E models showcase Toshiba’s commitment to durability and reliability. These units utilize high-quality components and advanced cooling technologies to ensure long-lasting performance. They also feature robust air filtration systems that purify the air, aiding in the reduction of allergens and dust particles, thus enhancing indoor air quality.

All of these models are equipped with a range of user-friendly features, including programmable timers, sleep modes, and adjustable airflow settings, giving users greater control over their indoor environment. Additionally, many of these units utilize eco-friendly refrigerants, aligning with global efforts to reduce environmental impact.

In summary, Toshiba’s RAS-M18EACV-E, RAS-M18EAV-E, RAS-B13EKVP-E, RAS-M16EKCVP-E, and RAS-M14EACV-E air conditioning systems offer a blend of innovative technologies, energy-efficient operation, and user-friendly features. Whether for residential cooling or light commercial use, these models stand out for their effectiveness and reliability, catering to varying demands while ensuring maximum comfort. Toshiba’s dedication to quality and sustainability is reflected in every model, making them a trustworthy choice for discerning consumers.