Toshiba RAS-M10EKCVP-E, RAS-M13EKCVP-E, RAS-M18EACV-E, RAS-M14EACV-E, RAS-M16EKCVP-E 103

Models: RAS-B10EKVP-E RAS-M14EAV-E RAS-B13EKVP-E RAS-M18EAV-E RAS-M10EKCVP-E RAS-M16EKCVP-E RAS-M14EACV-E RAS-M18EACV-E RAS-M13EKCVP-E

1 136
Download 136 pages 38.01 Kb
Page 103
Image 103
– 103 –

No.

Part name

 

Procedures

 

Remarks

 

 

 

 

 

 

"

High voltage

1)

Follow to the procedure in the item !.

 

 

 

generator

2)

Remove the drain guide.

 

 

 

 

 

 

 

 

 

 

 

Connector

 

 

 

 

 

Drain

 

 

 

 

guide

 

 

Air ionizer

 

3) To remove the air ionizer from the back body,

 

 

Push the

pull it toward you while pressing down on its left

 

 

and right claws. Disconnect the two leads

 

 

claw here

 

 

 

(black) connected to the air ionizer from where

 

 

 

they are fitted into the other components.

Push the

(Caution: do not remove the Faston.)

claw here

4) Disconnect the connectors of the high-voltage

 

Pull here

generator, and disconnect the four leads from

 

where they are fitted into the other components.

 

 

 

5)Remove the fixing screw which secures the high voltage generator, and remove the high voltage generator from the evaporator.

Screw

– 103 –