Indoor Unit Installation

Indoor Unit Installation

1.Pass the pipe through the hole in the wall, and hook the indoor unit on the installation plate at the upper hooks.

2.Swing the indoor unit to right and left to confirm that it is firmly hooked on the installation plate.

3.While pressing the indoor unit onto the wall, hook it at the lower part on the installation plate. Pull the indoor unit toward you to confirm that it is firmly hooked on the installation plate.

Hook here

aInstallation plate

Hook

Press (unhook)

 

For detaching the indoor unit from the installation plate pull the indoor unit toward you while pushing the bottom up at the specified places.

Push Push

Drainage

1. Run the drain hose at a downward sloped angle.

NOTE

• Hole should be made at a slight downward slant on the outdoor side.

Do not route the

Do not form the drain

drain hose upwards.

hose into a waved shape.

50 mm or more

Do not put the drain hose end into water.

Do not put the drain hose end in a drainage ditch.

2.Put water in the drain pan and make sure that the water is being drained outside.

3.When connecting extension drain hose, insulate the connection part of extension drain hose with shield pipe.

Shield pipe

Drain hose

Inside the room

 

Extension drain hose

CAUTION

Install the drain pipe for proper drainage. Improper drainage can result in water dripping inside the room.

This air conditioner has been designed to drain water collected from condensation which forms on the back of the indoor unit, to the drain pan. Therefore, do not locate the power cord and other parts at a height above the drain guide.

Wall

Drain guide

Space for pipes

– 68 –