system with easy access to the connections that it needs for power, local communications, and remote communications.

WARNING: Two people are required to lift the system.

CAUTION: To prevent electrostatic damage to the system and its components, make sure persons handling the system wear an antistatic device.

Rack-Mounted Installation

We recommend that you use a standard EIA distribution rack. See “Equipment Rack Requirements” on page 46 for rack information.

Installation Guidelines

Before installing the systems in a rack, consider the following guidelines:

You can install several models in a single 7-ft. (2.1-m) rack. Installing multiple systems in a single rack enables you to maximize your available space.

Install heavier systems on the bottom of the rack. Mount lighter systems higher in the rack.

Preparing the Equipment Racks

Following your installation plan, use a tape measure and marking pen to measure and mark space on each equipment rack for each system component. For horizontal spacing follow Network Equipment Building System (NEBS) requirements.

Installing the System

To complete the installation of the system in a rack, you need:

A Phillips screwdriver

Eight 10-32 x 3/8 Phillips screws (provided) for each model to be installed

To install the system in the rack:

14Rack-Mounted Installation