Juniper Networks C2000 Managing RAID Disks on a C-series Platform, Series Platform Data Storage

Models: C4000 C2000

1 76
Download 76 pages 40.79 Kb
Page 53
Image 53

Chapter 8

Managing RAID Disks on a C-series Platform

This chapter describes how to manage and view status information for RAID disks on a C-series platform. Topics include:

C-series Platform Data Storage on page 39

Managing Disks in a C-series Platform on page 40

C-series Platform Data Storage

A C-series platform provides data redundancy by supplying two hard drives (or disks) in a redundant array of independent disks (RAID). Both disks are configured as a RAID-1 mirror; this means that data is concurrently written to both disks. If one disk becomes inoperable, the remaining disk continues to be active, which allows the C-series platform to continue to function.

When you replace a faulty disk and initialize it, or disable and then enable a disk, the RAID controller copies all the data from the active disk to the enabled or initialized disk and establishes mirroring for the two disks.

The location of the disk mount for the disks depends on the model of the C-series platform:

C2000 system—Front of chassis

C4000 system—Back of chassis

When you access the disks in the disk mount:

Disk 0 is to the left.

Disk 1 is to the right.

You can also use the request disk identify command to make the LED for a specified disk blink to verify which disk is disk 0 and which is disk 1.

C-series Platform Data Storage 39

Page 53
Image 53
Juniper Networks C2000, C4000 manual Managing RAID Disks on a C-series Platform, Series Platform Data Storage