6 RECORDING (contd.)
6-6 Recording with an external activation signal
Recording can be started and stopped externally when an activation signal is input to the rear panel [EXT REC IN] terminal.
1.
CAMERA IN |
| AUDIO | ON I O | OFF | Connection |
|
|
| POWER |
| |
1 |
| IN |
|
| |
|
| 1 |
|
| 1. Connect an external control device. |
|
| COM SPARE SPARE COM RESET OUT FULL OUT |
| ||
1 | 2 | CAM SW ALARM | ALARM CLOCK EXT |
|
|
OUT IN1 | SPARE RESET RESET IN REC IN |
|
| ||
|
| 2 | CLOCK HDD |
|
|
| SIGNAL GND | AC IN 120 V | Connect the external control device to the rear panel |
MONITOR OUT | 50 Hz / 60 Hz | ||
OUT |
| ||
| AUDIO |
|
|
|
|
| [EXT REC IN] and [COM] terminals. |
2.
Signal input/output terminals
COM EXT REC
IN
External control device
Control signal of this unit (ground signal)
|
|
|
| HV:5V |
|
|
|
| LV:OV |
|
|
|
| |
|
|
| ||
|
|
|
| |
Start of recording | Stop | |||
|
| [EXT MODE] screen |
|
|
| [ E X T MOD E ] | JOG | ||
1 | . R E C M ODE |
| TR I G | |
2 . H DD F U L L O U T |
| O F F | ||
| [ A L A RM S ENS OR MOD E ] |
|
| |
1 . R E C M OD E |
| O F F | ||
2 . R E C D UR AT I ON | 1 8 0 S EC | |||
3 . P R E S E N S OR R E C |
| OF F | ||
4 . P R E S E N S OR |
|
| ||
|
| R E C D URA T I ON |
| 1 0 S EC |
Select the automatic recording operation.
Operation
2.Turn the power ON.
Check the connections and set the [POWER] switch on the rear panel to ON.
3.Set the menu switches.
Set the required menu switches. For details, refer to “Setting” on page 18.
[DVR MODE]
[REC QUALITY] : Set the recording picture quality.
[REC SPEED] : Set the recording speed.
[AUDIO REC] : Sets whether or not audio signals are recorded when menu switch <REC SPEED> is set to a position other than 1/5 or 1/10.
[EXT MODE]
[REC MODE] : Set the recording mode to use when an activation signal is input.
•When “TRIG” is selected, recording starts when a signal is input.
To stop recording, press the [STOP] button.
•When “MANUAL” is selected, recording is per-
formed as long as a signal is input. Reference:
4.Engage the Stop mode.
When an activation signal is input to the [EXT REC IN] terminal, recording starts automatically.
Memo:
●This function is disabled in the Timer Recording Standby mode.
6-7 Automatic restart of recording after power failure
If a power failure occurs, recording
To activate this function, set menu switch <POWER ON REC> to “ON”. When power is restored after a power outage, recording starts again in the same mode in use when power was lost.
| [ | DV R M ODE ] |
1 . R E C Q UA L I T Y | ||
2 | . R E C S P E ED | |
|
| R E C T I M E |
3 | . A UD I O R EC | |
4 | . P OWER O N RE C | |
5 . S E ARCH B U T T O N | ||
6 . S K I P D UR A T I O N | ||
7 | . R E P EA T REC | |
8 . T I M E D A T E R E C | ||
9 | . O PER AT E LO CK MO D E | |
1 | 0 . EXT S W I T C HER |
J O G NO RM 3 0
2 7 H
O N
O N
TI M E 1 HO U R O F F O N A L L
O N
Set to “ON”.
Caution:
●Because this device automatically performs a system check when power is restored after a power failure, there will be a delay before recording
30