6 RECORDING (contd.)

6-6 Recording with an external activation signal

Recording can be started and stopped externally when an activation signal is input to the rear panel [EXT REC IN] terminal.

1.

CAMERA IN

 

AUDIO

ON I O

OFF

Connection

 

 

 

POWER

 

1

 

IN

RS-232C

 

 

 

 

1

 

 

1. Connect an external control device.

 

 

COM SPARE SPARE COM RESET OUT FULL OUT

 

1

2

CAM SW ALARM

ALARM CLOCK EXT

 

 

OUT IN1

SPARE RESET RESET IN REC IN

 

 

 

 

2

CLOCK HDD

 

 

 

SIGNAL GND

AC IN 120 V

Connect the external control device to the rear panel

MONITOR OUT

50 Hz / 60 Hz

OUT

 

 

AUDIO

 

 

 

 

 

[EXT REC IN] and [COM] terminals.

2.

Signal input/output terminals

COM EXT REC

IN

External control device

Control signal of this unit (ground signal)

 

 

 

 

HV:5V

 

 

 

 

LV:OV

 

 

 

 

 

 

 

 

 

 

 

Start of recording

Stop

 

 

[EXT MODE] screen

 

 

 

[ E X T MOD E ]

JOG

1

. R E C M ODE

 

TR I G

2 . H DD F U L L O U T

 

O F F

 

[ A L A RM S ENS OR MOD E ]

 

 

1 . R E C M OD E

 

O F F

2 . R E C D UR AT I ON

1 8 0 S EC

3 . P R E S E N S OR R E C

 

OF F

4 . P R E S E N S OR

 

 

 

 

R E C D URA T I ON

 

1 0 S EC

Select the automatic recording operation.

Operation

2.Turn the power ON.

Check the connections and set the [POWER] switch on the rear panel to ON.

3.Set the menu switches.

Set the required menu switches. For details, refer to “Setting” on page 18.

[DVR MODE]

[REC QUALITY] : Set the recording picture quality.

[REC SPEED] : Set the recording speed.

[AUDIO REC] : Sets whether or not audio signals are recorded when menu switch <REC SPEED> is set to a position other than 1/5 or 1/10.

[EXT MODE]

[REC MODE] : Set the recording mode to use when an activation signal is input.

When “TRIG” is selected, recording starts when a signal is input.

To stop recording, press the [STOP] button.

When “MANUAL” is selected, recording is per-

formed as long as a signal is input. Reference: “5-3 Menu switch details” on page 19.

4.Engage the Stop mode.

When an activation signal is input to the [EXT REC IN] terminal, recording starts automatically.

Memo:

This function is disabled in the Timer Recording Standby mode.

6-7 Automatic restart of recording after power failure

If a power failure occurs, recording re-starts automatically as soon as the power supply is restored.

To activate this function, set menu switch <POWER ON REC> to “ON”. When power is restored after a power outage, recording starts again in the same mode in use when power was lost.

 

[

DV R M ODE ]

1 . R E C Q UA L I T Y

2

. R E C S P E ED

 

 

R E C T I M E

3

. A UD I O R EC

4

. P OWER O N RE C

5 . S E ARCH B U T T O N

6 . S K I P D UR A T I O N

7

. R E P EA T REC

8 . T I M E D A T E R E C

9

. O PER AT E LO CK MO D E

1

0 . EXT S W I T C HER

J O G NO RM 3 0

2 7 H

O N

O N

TI M E 1 HO U R O F F O N A L L

O N

Set to “ON”.

Caution:

Because this device automatically performs a system check when power is restored after a power failure, there will be a delay before recording re-starts.

30

Page 30
Image 30
JVC VR-510U Recording with an external activation signal, Automatic restart of recording after power failure, Connection