Sat Operation

LNB control menu

In the LNB control menu, the LNB supply voltage, 22 kHz control signal, DiSEqC and VSEC commands can be set. The voltage or signals are available on the RF socket. If the LNB supply voltage is activated, the red LED above the RF sockets lights up.

Selection of menu items: refer to section „Operating concept.“

LNB: U= 14,0V I=181mA

 

BACK

 

 

 

22kHz

off

14.0V on > 18.0V off>

09750 Lo 1>

DiSEqC

22 kHz control signal

The field lights up yellow, as soon as the softkey is pressed. The switchable 22 kHz signal superposes the

LNB voltage. By pressing the button once more, the 22 kHz signal is disconnected again.

14 V LNB supply voltage

VSEC The field lights up yellow, as soon as the softkey is pressed. The LNB supply

voltage of 14.0 V for the vertical polarisation is now switched on. For control, the LED above the RF input socket lights up. The voltage can be changed in the range of 10...20 V with the buttons, 1...9, or with the cursor buttons, ◄►. For nu- merical entry, the entry must be completed with „Enter.“ By pressing the button once more, the LNB supply voltage is disconnected again.

18 V LNB supply voltage

The field lights up yellow, as soon as the softkey is pressed. The LNB supply volt- age of 18.0 V for the horizontal polarisation is available on the input socket. The voltage can be changed in the ranged of 10...20 V with the buttons, 0...9, or with the cursor buttons, ◄►. For numerical entry, the entry must be completed with „Enter.“ By pressing the button once more, the LNB supply voltage is disconnected again.

The LNB voltage is

-disconnectable= 0V

-changeable from 10…20 V in 0.1-V increments

-short-circuit proof max. current 500 mA

LNB current draw

LNB: U = 14,6V I = 181mA

This field shows the current draw (I = 181 mA) and the supply voltage (14.6 V) of the LNB.