Kenwood TS-2000X, TS-B2000 instruction manual 119

Models: TS-2000X TS-B2000

1 152
Download 152 pages 3.22 Kb
Page 127
Image 127

21 APPENDIX

DC

Sets and reads the TX band status.

 

 

 

 

Parameters:

 

 

 

 

 

 

 

 

 

 

P1

 

 

 

 

 

 

 

 

 

 

 

0: Sets TX band to the main transceiver

 

1

2

3

4

5

6

7

8

9

10

 

1: Sets TX band to the sub-receiver ON

Set

 

 

 

 

 

 

 

 

 

 

D

C

 

 

 

 

 

 

 

 

P1

P2

;

 

 

 

 

 

P2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0: Sets CONTROL band to the main transceiver

 

1

2

3

4

5

6

7

8

9

10

 

1: Sets CONTROL band to the sub-receiver

Read

D

C

;

 

 

 

 

 

 

 

When the P1 parameter changes, the same parameter is set

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

to P2.

Answer

D

C

P1

P2

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DN

Emulates the microphone DWN key.

 

 

 

 

Parameters:

 

 

 

 

 

 

 

 

 

 

P1

 

 

 

 

 

 

 

 

 

 

 

00 ~ 99

 

1

2

3

4

5

6

7

8

9

10

 

 

Set

 

 

 

 

 

 

 

 

 

 

 

D

N

P1

P1

;

 

 

 

 

 

If no P1 paramter is specified, the command is interpreted as

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 step down.

 

1

2

3

4

5

6

7

8

9

10

 

In Memory mode and Quick Memory mode, the command

Read

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

without a parameter is treated as a Memory channel down

 

 

 

 

 

 

 

 

 

 

 

command. With parameters, it is treated as the frequency

 

1

2

3

4

5

6

7

8

9

10

down command.

Answer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DQ

Sets and reads the DCS function status.

 

 

 

Parameters:

 

 

 

 

 

 

 

 

 

 

P1

 

 

 

 

 

 

 

 

 

 

 

0: DCS function OFF

 

1

2

3

4

5

6

7

8

9

10

 

1: DCS function ON

Set

D

Q

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

 

Read

 

 

 

 

 

 

 

 

 

 

 

D

Q

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

 

Answer

 

 

 

 

 

 

 

 

 

 

 

D

Q

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EX

Sets or reads the Extension Menu.

 

 

 

 

Parameters:

 

 

 

 

 

 

 

 

 

 

P1

 

 

 

 

 

 

 

 

 

 

 

000 ~ 999 : Menu No. (1st)

 

1

2

3

4

5

6

7

8

9

10

 

P2

 

 

 

 

 

 

 

 

 

 

 

 

E

X

P1

P1

P1

P2

P2

P3

P4

P5

00 ~ 99: Menu No. (2nd)

 

P3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 ~ 9: Menu No. (3rd)

 

11

12

13

14

15

16

17

18

19

20

 

P4

Set

 

 

 

 

 

 

 

 

 

 

P5

P5

P5

P5

P5

P5

P5

P5

P5

P5

0 ~ 9: Menu No. (4th)

 

 

P5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A string of characters

 

21

22

23

24

25

26

27

28

29

30

 

(Variable length)

 

 

 

 

 

 

 

 

 

 

 

 

P5

P5

P5

P5

P5

;

 

 

 

 

 

 

 

 

 

If the 2nd and 3rd menus are not available, set “00”.

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

Specify 1 digit only.

Read

 

 

 

 

 

 

 

 

 

 

Display brightness:

E

X

P1

P1

P1

P2

P2

P3

P4

;

EX00000000; (Dimmer OFF).

 

 

 

 

 

 

 

 

 

 

 

 

EX00000003; (Dimmer level 2).

 

1

2

3

4

5

6

7

8

9

10

 

Menu 29B, 31, 33, 51A ~ E, 59 and 62C have 2-digit

 

E

X

P1

P1

P1

P2

P2

P3

P4

P5

parameters.

 

Menu 61C (P5): 000 ~ 999 (3-digit).

 

 

 

 

 

 

 

 

 

 

 

Menu 62A ~ B (P5): A maximum of 8 characters.

 

11

12

13

14

15

16

17

18

19

20

 

Menu 45A (P3): 0 ~ 9 for DTMF Memory channel number.

Answer

 

 

 

 

 

 

 

 

 

 

P5

P5

P5

P5

P5

P5

P5

P5

P5

P5

Menu 45A (P4): 0 (DTMF), 1 (Code)

 

Menu 45A (P5): A maximum of 16 digits. If the first character

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

is a space character, the name will be cleared. 62A and 62B

 

21

22

23

24

25

26

27

28

29

30

 

become “NO CALL”.

 

 

 

 

 

 

 

 

 

 

 

 

P5

P5

P5

P5

P5

;

 

 

 

 

Although you can turn Menu No. 55 ON, using the EX

 

 

 

 

 

command, you must use the TC 1; command to turn it OFF.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

119

Page 127
Image 127
Kenwood TS-2000X, TS-B2000 instruction manual 119