21 APPENDIX

MD

Recalls or reads the operating mode status.

 

 

 

 

Parameters:

 

 

 

 

 

 

 

 

 

 

 

 

P1

 

 

 

 

 

 

 

 

 

 

 

 

 

1: LSB

 

1

 

2

3

4

5

6

7

8

9

 

10

 

 

 

2: USB

Set

 

 

 

 

 

 

 

 

 

 

 

 

M

 

D

 

 

 

 

 

 

 

 

 

 

P1

;

 

 

 

 

 

 

 

3: CW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4: FM

 

1

 

2

3

4

5

6

7

8

9

 

10

 

 

 

5: AM

Read

M

 

D

;

 

 

 

 

 

 

 

 

6: FSK

 

 

 

 

 

 

 

 

 

 

7: CR-R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

2

3

4

5

6

7

8

9

 

10

8: Reserved

Answer

M

 

D

P1

;

 

 

 

 

 

 

 

9: FSK-R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MF

Sets or reads Menu A or B.

 

 

 

 

 

 

Parameters:

 

 

 

 

 

 

 

 

 

 

 

 

P1

 

 

 

 

 

 

 

 

 

 

 

 

 

0: Menu A

 

1

 

2

3

4

5

6

7

8

9

 

10

 

 

 

1: Menu B

Set

 

 

 

 

 

 

 

 

 

 

 

 

M

 

F

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

2

3

4

5

6

7

8

9

 

10

 

Read

 

 

 

 

 

 

 

 

 

 

 

 

 

M

 

F

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

2

3

4

5

6

7

8

9

 

10

 

Answer

M

 

F

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MG

Sets or reads the Microphone gain status.

 

 

 

 

Parameters:

 

 

 

 

 

 

 

 

 

 

 

 

P1

 

 

 

 

 

 

 

 

 

 

 

 

 

000 (min.) ~ 100 (max.)

 

1

 

2

3

4

5

6

7

8

9

 

10

 

 

 

 

Set

M

 

G

P1

P1

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

2

3

4

5

6

7

8

9

 

10

 

Read

 

 

 

 

 

 

 

 

 

 

 

 

 

M

 

G

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

2

3

4

5

6

7

8

9

 

10

 

Answer

 

 

 

 

 

 

 

 

 

 

 

 

M

 

G

P1

P1

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ML

Sets or reads the MONITOR function level.

 

 

 

 

Parameters:

 

 

 

 

 

 

 

 

 

 

 

 

P1

 

 

 

 

 

 

 

 

 

 

 

 

 

000: MONITOR OFF

 

1

 

2

3

4

5

6

7

8

9

 

10

 

 

 

001 (min.) ~ 009 (max.)

Set

 

 

 

 

 

 

 

 

 

 

 

 

M

 

L

P1

P1

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

2

3

4

5

6

7

8

9

 

10

 

Read

M

 

L

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

2

3

4

5

6

7

8

9

 

10

 

Answer

M

 

L

P1

P1

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MO

Sets the MONITOR function ON/ OFF in Sky Commander

 

Parameters:

mode.

 

 

 

 

 

 

 

 

 

 

P1

 

 

 

 

 

 

 

 

 

 

 

 

 

0: MONITOR OFF

 

1

 

2

3

4

5

6

7

8

9

 

10

 

 

 

1: MONITOR ON

Set

 

 

 

 

 

 

 

 

 

 

 

 

M

 

O

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

2

3

4

5

6

7

8

9

 

10

 

Read

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

2

3

4

5

6

7

8

9

 

10

 

Answer

M

 

O

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

127

Page 135
Image 135
Kenwood TS-2000X, TS-B2000 instruction manual 127, Monitor OFF