21 APPENDIX

Command

Short

Default

Parameter

Description

Name

 

 

 

 

 

 

 

 

 

 

 

 

 

Specifies the period of random number generation intervals

SLOTTIME

SL

3

0 ~ 250

for the PERSIST/SLOTTIME method. The unit of the

 

 

 

 

parameter is 10 milliseconds.

 

 

 

 

 

TRACE

TRAC

OFF

ON/ OFF

When ON, causes the TNC to display all received packets

in their entirety.

 

 

 

 

 

TRIES

TRI

0

0 ~ 15

Specifies the number of transmission retries programmed in

the retry counter.

 

 

 

 

 

 

 

 

 

TXDELAY

TX

50

0 ~ 120

Specifies the time delay between PTT ON and the start of

transmission. The unit of the parameter is 10 milliseconds.

 

 

 

 

 

 

 

 

 

 

 

 

Call1 (VIA

Specifies call signs to send a packet in Unprotocol mode.

UNPROTO

U

CQ

call2, call3,

Call1 is the call sign of the destination. Call2 to call9 are

 

 

 

... call9)

call signs of stations to be digipeated through.

XFLOW

X

ON

ON/ OFF

Causes the TNC to perform software flow control when ON,

or hardware flow control when OFF.

 

 

 

 

 

Note:

If you are using a PC with a communication program to control this built-in TNC, prepare the RS-232C cable (straight) for connecting to the COM teminal on the transceiver. Then, set the same communication speed by accessing Menu No. 56. Select the same communication speed and the communications parameters. They must be set 8-bit, 1-stop bit, Non-parity, except for 4800 bps. The 4800 bps is also used for the Quick Data Transfer function {page 80} and the communication parameters are fixed as 8-bit, 2-stop bit, Non-parity format.