Kenwood TS-B2000, TS-2000X instruction manual 132, Pm Off

Models: TS-2000X TS-B2000

1 152
Download 152 pages 3.22 Kb
Page 140
Image 140

21 APPENDIX

PK

Reads the Packet Cluster data.

 

 

 

 

 

 

Parameters:

 

 

 

 

 

 

 

 

 

 

 

This command is used in conjunctin with the AI command.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

 

10

P1

Set

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency in Hz (11-digit)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P2

 

1

2

3

4

5

6

7

8

9

 

10

 

 

Callsign (12-digit)

Read

 

 

 

 

 

 

 

 

 

 

 

P3

 

 

 

 

 

 

 

 

 

 

 

 

Comments (20-digit)

 

1

2

3

4

5

6

7

8

9

 

10

P4

 

 

 

 

 

 

 

 

 

 

 

 

Time (5-digit)

 

P

K

P1

P1

P1

P1

P1

P1

P1

P1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

12

13

14

15

16

17

18

19

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P1

P1

P1

P2

P2

P2

P2

P2

P2

P2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21

22

23

24

25

26

27

28

29

 

30

 

 

P2

P2

P2

P2

P2

P3

P3

P3

P3

P3

 

Answer

 

 

 

 

 

 

 

 

 

 

 

 

31

32

33

34

35

36

37

38

39

 

40

 

 

 

 

 

P3

P3

P3

P3

P3

P3

P3

P3

P3

P3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

41

42

43

44

45

46

47

48

49

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P3

P3

P3

P3

P3

P4

P4

P4

P4

P4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

51

52

53

54

55

56

57

58

59

 

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PL

Sets and reads the Speech Processor input/ output level.

 

Parameters:

 

 

 

 

 

 

 

 

 

 

 

P1

 

 

 

 

 

 

 

 

 

 

 

 

Input level:

 

1

2

3

4

5

6

7

8

9

 

10

 

 

000 (min.) ~ 100 (max.)

Set

P

L

 

 

 

 

 

 

 

 

 

P1

P1

P1

P2

P2

P2

;

 

 

P2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output level:

 

1

2

3

4

5

6

7

8

9

 

10

 

 

000 (min.) ~ 100 (max.)

Read

P

L

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

 

10

 

Answer

 

 

 

 

 

 

 

 

 

 

 

 

P

L

P1

P1

P1

P2

P2

P2

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PM

Recalls the PM (Programmable Memory).

 

 

 

 

Parameters:

 

 

 

 

 

 

 

 

 

 

 

P1

 

 

 

 

 

 

 

 

 

 

 

 

0: PM OFF

 

1

2

3

4

5

6

7

8

9

 

10

 

 

1 ~ 5 (PM channel number)

Set

P

M

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

 

10

 

Read

 

 

 

 

 

 

 

 

 

 

 

 

P

M

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

 

10

 

Answer

 

 

 

 

 

 

 

 

 

 

 

 

P

M

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PR

Sets or reads the Speech Processor function ON/ OFF.

 

Parameters:

 

 

 

 

 

 

 

 

 

 

 

P1

 

 

 

 

 

 

 

 

 

 

 

 

0: Speech Processor OFF

 

1

2

3

4

5

6

7

8

9

 

10

 

 

1: Speech Processor ON

Set

P

R

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

 

10

 

Read

P

R

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

 

10

 

Answer

 

 

 

 

 

 

 

 

 

 

 

 

P

R

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

132