Flash Memory Upgrade

10.2.3Upgrading Firmware

Follow these steps to upgrade the firmware:

1.Double click the KFR-Programmer desktop icon.

The KFR-Programmer window appears (see Figure 31).

Figure 31: The KFR-Programmer Window

2.Select the required COM Port1.

3.Press the File button to select the .s19 firmware file included in the package.

4.Press the Send button to download the file. The Send button lights red.

5.Wait until downloading is completed and the red Send button turns off.

6.Set DIP 1 on the PROGRAM dipswitches located in the CONTROLLER area OFF.

10.2.4Installing the Web Applet2

Follow these steps to install the Web Applet:

1.Connect RC device to your PC through computer networking.

2.Start RC Configuration Software and connect to the RC device (see RC Configuration and Installation Guide).

3.In the Device menu select Upgrade Applet option and browse to MC.dat file included in the package

Wait until uploading is completed and the success message appears. Click OK.

1 To which the VP-23RC is connected on your PC

2 This section is applicable only to firmware version 26.0 and higher and requires RC Configuration Software version 1.26.0.38 and higher