Addendum: Scalers Group
8.Under the Utility>Output Setting>User Mode Setting there is a new option: “Set Current”. This feature lets you apply the parameters of the currently selected output resolution to the User Define output resolution (Utility>Output Setting>Resolution). This set of parameters can be used as a “starting point” to adjust parameters according to the requirements of the signal receiver. The changes to the User Define parameters are applied immediately and require confirmation in the same part of the OSD.
9.In the OSD under UTILITIES>ADVANCED there is new item “User Define Measure”. This feature lets you modify the automatically detected parameters of the input graphic signal and save them in one of 3 sets for further use. The changes are applied in real time and therefore can be monitored directly on the screen. This feature is especially useful in working with
H Total: | Horizontal total |
H Start: | Horizontal active start point |
H Active: | Horizontal active region |
V Start: | Vertical active start point |
V Active: | Vertical active region |
Ch Pump: | Charge Pump current |
Color: | Color Format |
10.Under the Utility>PIP Setting>PIP Size, there is a new option: “User Define”. This feature lets you set the size of the PIP to your exact needs. To use this option, select “User Define”, then press the “PIP User Define” bar and set the PIP
11.By pressing the +,
12.New firmware supports an updated set of
13.Under Geometry>Scale>Aspect Ratio there is a new option: “User Define”. This feature lets you adjust the geometry of the outputted picture.
14.A new refresh rate for HDTV resolutions. This new feature supports the HDTV outputs with 50Hz refresh rate2.
1255 corresponds to a full screen
2This option applies to machines that support HDTV resolutions
A2