VP-725XLA Communication Protocol

Control Type

Function

Parameter

Description

Set

Get

 

 

 

3: HDMI4

Error when SELECT ≠ Video Group / Audio

 

 

 

 

Group / AV Group

 

 

 

0: COMP1

Select COMP group channel

0

1

154

1: COMP2

Note :

2: COMP3

Error when SELECT ≠ Video Group / Audio

 

 

 

 

 

 

3: COMP4

Group / AV Group

 

 

 

0: YC1

Select YC group channel

0

1

155

1: YC2

Note :

2: YC3

Error when SELECT ≠ Video Group / Audio

 

 

 

 

 

 

3: YC4

Group / AV Group

 

 

 

0: CV1

Select CV group channel

0

1

156

1: CV2

Note :

2: CV3

Error when SELECT ≠ Video Group / Audio

 

 

 

 

 

 

3: CV4

Group / AV Group

 

 

 

0: VGA1

 

 

 

 

1: VGA2

 

 

 

 

2: VGA3

 

 

 

 

3: VGA4

 

 

 

 

4: HDMI1

 

 

 

 

5: HDMI2

 

 

 

 

6: HDMI3

 

 

 

 

7: HDMI4

 

 

 

 

8: COMP1

Select Master Input channel

 

 

 

9: COMP2

 

 

 

Note :

0

1

157

10: COMP3

Error when SELECT ≠ Scaler / Master Audio /

 

 

 

11: COMP4

 

 

 

Master AV

 

 

 

12: YC1

 

 

 

 

 

 

 

13: YC2

 

 

 

 

14: YC3

 

 

 

 

15: YC4

 

 

 

 

16: CV1

 

 

 

 

17: CV2

 

 

 

 

18: CV3

 

 

 

 

19: CV4

 

 

 

 

20: USB

 

 

 

 

0: All Off

 

0

1

158

1: Override

MIC Control

2: Mix

 

 

 

 

 

 

 

3: Talk Over

 

0

1

159

-30 ~ +10

VGA Group In Volume

0

1

160

-30 ~ 10

VGA Group Out Volume

0

1

161

-30 ~ +10

HDMI Group In Volume

0

1

162

-30 ~ 10

HDMI Group Out Volume

0

1

163

-30 ~ +10

COMP Group In Volume

0

1

164

-30 ~ 10

COMP Group Out Volume

0

1

165

-30 ~ +10

YC Group In Volume

0

1

166

-30 ~ 10

YC Group Out Volume

0

1

167

-30 ~ +10

CV Group In Volume

0

1

168

-30 ~ 10

CV Group Out Volume

0

1

169

-30 ~ +10

Master In Volume

0

1

170

-100 ~ 24

Master Out Volume

0

1

171

-100 ~ 24

MIC In Volume

0

1

172

0: OSD ON = disable

To Enable / Disable OSD ON

1: OSD ON = enable

 

 

 

 

 

 

 

0: Pip source select = 0

Hot key PIP source select, same as remote

0

1

173

control key

1: Pip source select = 1

 

 

 

- PIP Source

 

 

 

 

0

1

174

0: 1/25 (for Get Command)

Hot key PIP size, same as remote control key

1: 1/16 (for Get Command)

- PIP Size

 

 

 

59

Page 63
Image 63
Kramer Electronics user manual VP-725XLA Communication Protocol